INSTALLER/CONFIGURATION MENU
Press the Menu button for at least 5 seconds. The display will show item #1 in the table below. Press Menu to advance to the 
next menu item. Press 
 or 
 to change a menu item. Shaded items available on 1F85 model only.
INSTALLER/CONFIGURATION MENU        
MENU
REF.
HP SS
PRESS
BUTTON
DISPLAYED
(FACTORY DEFAULT)
Press 
 or 
 to
select from listed options
COMMENTS
1
1
1
MENU
(MS 2)
HP 1, SS 1
Selects Multi-Stage (MS 2 No Heat Pump),
Heat Pump 1 (HP 1, 1 compressor),
or Single Stage (SS 1)
2
2
2
MENU
(GAS) for SS or MS
(ELE) for HP
ELE
GAS setting: furnace controls the blower
ELE setting: thermostat controls the blower
3
3
3
MENU
CS (0)
(Disabled)
1, 2, 4, 5, 6
Selects Cool Savings
Value 1 (low) to 6 (high), Value 0 Disables Featrue
4
4
4
MENU
E (On)
OFF
Selects Energy Management Recovery (EMR)
On or OFF. 1F85 only
5
5
MENU
CR Heat (ME)
SL, FA
Adjustable Anticipation:
Selects heating cycle rate for MS or SS
6
5
MENU
CR Heat Pump
(ME)
SL, FA
Adjustable Anticipation (Heat Pump) (only
when heat pump selected in #1)
7
6
6
MENU
CR Cool (ME)
or
CR Emer (FA)
SL, FA
SL
Adjustable Anticipation:
Selects the cycle rate for cooling (only when
MS 2 or SS 1 is selected in item 1.) or
Selects the cycle rate for Emergency mode
and Auxiliary stage if Heat Pump is selected
in item 1.
8
7
7
MENU
CL (OFF)
CL On
Compressor Lockout Time
9
8
8
MENU
Heat Auto
 
Cool Off
Heat Cool Off,
Heat Off with Fan icon,
Heat Off without Fan icon
Cool Off, Auto Off
System Mode Confi guration
with Automatic Changeover capability
10
9
9
MENU
dL (On)
dL OFF
Selects Display Light On or OFF
11
10
10
MENU
0
(current temperature)
1 HI, 2 HI, 3 HI, 4 HI,
1 LO, 2 LO, 3 LO, 4 LO
Adjustable Ambient Temperature Display
12
11
11
MENU
°
F
°
C
Selects Fahrenheit/Celcius Temperature Display
13
12
12
MENU
L Heat
(90)
L 62 to L 89
Selects Limited HEAT Range
14
13
13
MENU
L Cool
(45)
L 46 to L 82
Selects Limited COOL Range
15
14
14
MENU
P3
P0, P2
Defaults for 5-1-1 programming (P3) but non-
programmable (PO) or 5-2 programming (P2)
is available on most models. 1F85 only
16
15
15
MENU
Heat AS (On)
OFF
Automatic Schedule for heat mode. 1F85 only.  
NA to Cool only system.
17
16
16
MENU
Cool AS (On)
OFF
Automatic Schedule for cool mode. 1F85 only. 
NA to Heat only system.
18
17
MENU
Heat FA (On)
OFF
Fast Heat option may be disabled by
selecting OFF. NA to SS confi g. 
NA to Cool only system.
19
18
MENU
Cool FA (On)
OFF
Fast Cool option may be disabled by
selecting OFF. NA to SS confi g. 
NA to Heat only system.
20
19
17
MENU
dS (On)
OFF
Selects Automatic daylight Savings Time option
On or OFF. 1F85 only
21
20
18
MENU
Change Filter (OFF)
On
Selects Filter Change-out Indicator On or OFF.
MENU
Change Filter (200 h)
25-1975 h
Change Filter time in 25 hour increments. This
menu only appears if On is selected in above.
22
21
19
MENU
Cool On (o)
Heat On (b)
Selects operation of the reversing valve terminal 
(O/B) output as an O or B terminal.
22
20
RUN 
SCHED
Retuns to Normal Operation