Replacing Fuses
To replace a blown fuse on the accessory, complete the following steps.
1.
Unplug the accessory power.
2.
Remove all signal wires and cables from the accessory.
3.
Unscrew the two screws from a side panel with a Phillips head screwdriver and remove the side 
panel as shown in Figure 4.
Figure 4.  
Removing the Circuit Board
4.
Slide the circuit board out.
5.
Replace the blown fuse while referring to Figure 1 for the fuse location.
Spare fuses can be found next to each fuse location as shown in Figure 1. You also can order 
additional fuses from Littelfuse at 
www.littelfuse.com
 or from electronics distributors.
Fuse
Littelfuse Part Number
Description
Power
0448002
2A, 125V lead-free very fast-acting NANO
2
 subminiature 
ceramic surface mount fuse, 6.10 
× 2.69 mm
Iso Out 0, 
Iso Out 1, 
RS-232 
0448.200
200mA, 125V lead-free very fast-acting NANO
2
 
subminiature ceramic surface mount fuse, 6.10 
× 2.69 mm