The Informant™ 2 
 
 
0019-9211 Rev 9 
 
2.8.  Locating a Gas Leak 
 
After the detector is turned on and allowed to warm up, observe that 
none of the gas-level LEDs should be glowing. Also note that both the 
probe tip should be blinking and the audible indicator ticking once per 
second. All of these indicators show that the detector is currently not 
detecting a change in gas concentration. 
 
 
IMPORTANT:  The detector’s function is to detect a change 
in gas levels, and not to make a quantitative measurement of 
the level. The technique of locating a leak by detecting a 
change in level allows an operator to quickly locate the 
source of a leak without making manual sensitivity 
adjustments, or being concerned about the background 
vapor or gas level in the surrounding area. 
 
 
Leak testing can be performed with the probe either “docked” in its 
storage position for close-up leak testing, or unfolded to its maximum 
length of 20 inches (508 mm) for locating leaks in hard-to-reach areas.  
 
Begin leak testing by slowly moving the probe toward the area to be 
tested. If surfaces are dirty or wet, wipe them off with a clean shop towel 
to prevent the filter from clogging. Avoid allowing water to enter the 
probe tip. 
 
When the detector first “sees” an increased gas level, all gas-level LEDs 
immediately glow along with the probe tip blinking and audible indicator 
ticking at a very rapid rate. If movement of the probe is stopped for more 
than 10 seconds, the detector’s automatic self-zero feature will cause all 
gas-level LEDs to turn off, along with decreasing the blinking and ticking 
rate of the probe tip and audible indicator, respectively. 
 
Once the presence of gas has been determined and the detector allowed 
to self zero, moving the probe toward the source of the leak will once 
again cause the detector to respond in a positive manner. After which, if 
the probe is moved away from the leak source, the detector will respond 
with a lower gas-level indication.