The Informant™ 2 
 
 
0019-9211 Rev 9 
 
19 
4.  TROUBLESHOOTING 
 
The following table lists the causes and remedies for the most common 
problems that may occur with the detector.  
 
If the information in Table 1 does not solve the problem, or for help with 
any problem that is not listed, please contact one of the Bacharach 
Sales/Service Centers listed in Section Parts & Service
 
Table 1. Troubleshooting Guide 
Symptom 
Probably Cause and Remedy 
Instrument does not 
turn on. 
a. Batteries are dead or installed 
backward. Install four fresh ‘AA’ 
alkaline batteries per Section Battery 
Installation
.  
b. Possible faulty refrigerant sensor. 
-Remove refrigerant sensor and turn on 
detector. If detector now turns on, and 
after warm-up shows a bad sensor (see 
sensor failure indication below), replace 
sensor per Section Sensor 
Replacement. 
c. Loose printed circuit board connector. 
Disassemble detector and ensure that 
all connectors are securely attached to 
the printed circuit board. See Figure 8.
 
The middle gas-level 
LED on both displays 
glows steady.   
Sensor depleted or faulty. Replace per 
Section Sensor Replacement
All gas-level LEDs 
momentarily light full 
scale and then turn 
off, leaving both the 
audible tick rate and 
probe tip blink rate at 
-elevated levels. 
Refrigerant sensor “flooded” with 
refrigerant. Move the detector to an area 
of fresh air for about 1 minute, or until all 
indicators return to their idle state.