Component description
Components and function description
Here we describe the function and 
specification of the most important 
components. Certain components are found 
only in more highly specified machines or in 
particular markets. See the Troubleshooting 
chapter for fault and information codes.
CU (Control Unit)
The CU (Control Unit) functions as both a 
control panel and a logic component. The 
control panel is equipped with knobs/buttons 
for selecting programmes, Start/Stop buttons 
and a display. It is an integrated part of the 
CU and cannot be replaced separately. The 
logic component manages functions needed 
for drying programmes and diagnosis. The 
CU has an internal power supply for the logic 
component. In the event of a fault, the CU 
can diagnose a number of components and 
functions, and a total of 4 fault codes can be 
displayed. To facilitate troubleshooting there 
is a component testing function in which the 
outputs are activated according to a special 
sequence.
Power supply
Mains voltage, built-in internal voltage 
converter for the logic component.
Thermistors
The thermistors are of the NTC type (Negative 
Temperature Coefficient), which means their 
resistance decreases as temperature increases.
Thermistor 1 is in the air duct on the front frame, 
after the internal impeller. If there is an interruption 
in the thermistor circuit or if it short circuits, the 
drying programme stops and the display shows 
“Thermistor fault”.
  Purpose: Measures the temperature of the air that 
has passed the load and controls the drying process 
and the heating element.
Thermistor 2 is on condenser dryers located after the 
condenser and on heat pump dryers located on the 
evaportator pipe by the comperssor. 
  Purpose:
 Measures the temperature of the 
dehumidified air, the value of which is used as a 
parameter in the drying process.
Resistance values for thermistors 1 and 2
Temperature
Resistance
20°C
5989
25°C
4869
30°C
3946
35°C
3197
40°C
2598
45°C
2126
50°C
1758
55°C
1471
60°C
1240
65°C
1043
70°C
857
Personal notes