Инструкции По Обслуживанию для Summit TDC112C

Скачать
Страница из 40
Component description
Components and measurement values
The specified resistance values apply at room temperature (about 20°C/68°F). Values within 
±10% are considered normal.
Article no.
Component
Measurement value
Comment
80 839 15
Motor 50 Hz,  
220/240 V
Winding resistance: 
cable colour red-white 26.5 
Ω 
cable colour red-blue 53.5 
Ω
cable colour white-blue 
27.0 Ω 
Current: 0.7 A; 140 W; 
2850 rpm
80 839 16
Motor 60 Hz,  
220/240 V
Winding resistance: 
cable colour red-white 26.5 
Ω 
cable colour red-blue 53.5 
Ω
cable colour white-blue 
27.0 Ω
Current: 0.7 A; 140 W; 
3300 rpm
The motor is a 2-pin motor and is 
directly connected to the fan for 
internal air and the gearing for driving 
the cylinder. On condenser dryers, the 
motor also drives the fan for external air. 
80 903 13
Capacitor
8 μF
50 Hz
80 903 14
Capacitor
6 μF
60 Hz
80 902 70
Capacitor heat pump
17 μF
50 Hz
80 902 71
Capacitor heat pump
60 Hz
80 821 28
Condensate pump
50 Hz
80 846 48
Condensate pump
60 Hz
80 762 02
EMC-filter with inductor
The filter eliminates interference to and 
from the machine.
80 833 44
Thermistor
4.8 kΩ (at 25°C)
The thermistor controls temperature 
regulation. If the thermistor is short-
circuited or detaches from the control 
unit, the programme is stopped.
80 773 85
Thermostat 150
150°C automatic
The thermostat/overheating cut-out 
stops the programme if the temperature 
becomes too high. 
80 792 00
Thermostat 135
135°C automatic
80 902 24
Thermostat 110
110°C automatic
80 761 04
Door switch
The front door triggers a door switch 
which stops the programme when the 
door is open. If the door has been opened 
and closed during the programme the 
machine must be restarted using the 
Start/Stop button.
80 761 03
Microswitch float
Overflow guard
If both containers in the tumble dryer 
are full the programme is stopped by 
a float switch installed in the lower 
container. “Over flow” is indicated on 
the display.
Electrical connection
Condenser 1950W/10A-
2500W/16A
Vented 1950W/10A-
3000W/16A
Heat pump 1300W/10A
Heating Water Circuit 
1950W/10A
The machine is delivered as single phase 
and can be switched between 10 A and 16 
A. The control buttons are used to make 
the switch via the software. Does not apply 
to Heat Pump or Heating Water Circuit.
Service Manual TD70.C