Инструкции По Установке для Maytag MLE24PDAWW

Скачать
Страница из 44
20
20
If cycle counter (9.0C) is selected, the following is true:
100  Represents the number of cycles in HUNDREDS.  1 02 = 200
200  Represents the number of cycles in ONES. 
2 25 = 
2
25
 
 
TOTAL = 225  
 
 
           cycles
 
This is “VIEW ONLY” and cannot be cleared.
 
Press the PERM. PRESS key pad once to advance  
 
to next code. 
If money counter (1.0C or 1.C0) is selected, the following is true:
300  Number of dollars in HUNDREDS. 
3 01 = $100.00
400  Number of dollars in ONES. 
4 68 = $
1
68.00
500  Number of CENTS. 
5 75 = $
1
00.75
TOTAL = $168.75
END OF SET-UP PROCEDURES
EXIT FROM SET-UP MODE
n
STACKED MODELS: Turn access panel key back to original 
position.
DIAGNOSTIC GUIDE
If the set-up mode is entered and one of the following has occurred, 
the appropriate diagnostic code will be in the display.
STACKED DRYERS
            CODE                              EXPLANATION
Invalid dryer door circuit state state – 
Sahara control does not differentiate 
between invalid state and open door 
state.
CCU error – Sahara control will send 
this error when the motor feedback 
circuit is sensing voltage with the door 
open or when the motor shouldn’t be 
on. The control does not know if the 
relay is bad (stuck on), the relay drive 
circuit is bad (shorted causing the 
motor relay to stay on), or the relay 
fedback circuit is bad.
Low voltage
CCU error – Sahara control will send 
this error when the motor feedback 
circuit is sensing voltage with the door 
open or when the motor should not  
be on. The control does not know if  
the relay is bad (stuck on), the relay 
drive circuit is bad (shorted, causing 
the motor relay to stay on), or the relay 
fedback circuit is bad.
Coin 2 Failure
Upper dryer motor sense circuit error 
on control board or due to power line 
interference (upper dryer cycles and 
upper dryer display disabled until 
diagnostic code is manually cleared).
Gen 2 Debit Card
Lower dryer door sense error on 
control board or due to power line 
interference (lower dryer cycles and 
lower dryer display disabled until 
diagnostic code is manually cleared).
Upper dryer motor control circuit error 
(upper dryer cycles and upper dryer 
display disabled until diagnostic code 
is manually cleared).
d 1
d 12
d 4
d 9
d 13
d 16
F-01
F-01
F-01
d 9
d 13
d 16
d 17
d 20
d 17
d 20