Page 4
STEP 2   
Electrical Connection
NOTES: 
1.  The power pack systems requires a properly grounded, 120 VAC, 60 Hz., 15 Amp electrical 
service. 
2.  Maximum full line load is 8 amps. 
3.  Always use a dedicated circuit.
WARNINGS:
1.  Ensure that the power supply is disconnected before proceeding.
2.  Verify that the power supply matches the ratings found on the appliance data plate before 
proceeding.
3.  The complete appliance must be properly grounded at all times when electrical power is applied.
4.  Do not ground the appliance with the neutral (white) house supply wire. A separate ground wire 
must be utilized.
5.  If aluminum house supply wiring is used, splice the appliance copper wires to the aluminum 
house wiring with special connectors designed and agency-certified for this purpose. Follow the 
connector manufacturer’s recommended procedure carefully. Improper connection can result in 
a fire hazard.
6.   Failure to complete electrical connections properly may result in a damaged or non-functional 
system. Follow the wiring diagrams carefully to ensure a proper installation. 
L1
N1
Gnd
L2
N2
Gnd
GRN
WHT
120VAC, 60Hz, 15A
Supply power from
dedicated circuit breaker
BLK
IVS
It is the owner’s responsibility to ensure that a qualified electrician performs the electrical connection of this appliance. The electrical 
installation, including minimum supply wire size, must comply with the National Electric Code ANSI/NFPA 70-1990* (or to the latest revision) 
and local codes and ordinances.
*A copy of this standard may be obtained from:
 
National Fire Protection Association
 
1 Batterymarch Park
 
Quincy, Massachusetts 02269-9101
Figure 6:
IVS Wiring Diagram
GRN
WHT
BLK
L1
N1
Gnd
L2
N2
Gnd
L2
N2
Gnd
GRN
WHT
BLK
GRN
WHT
120VAC, 60Hz, 15A
Supply power from
dedicated circuit breaker
BLK
GRN
WHT
BLK
IVS
ILB
L1
N1
Gnd
L2
N2
Gnd
L2
N2
Gnd
GRN
WHT
120VAC, 60Hz, 15A
Supply power from
dedicated circuit breaker
BLK
GRN
WHT
BLK
GRN
WHT
BLK
IVS
REMP
Figure 7:
IVS with ILB Wiring Diagram
Figure 8:
IVS with REMP Wiring 