Address Map
  
The core of the UART function is supplied by the EXAR XR16L788 chip. 
  
This chip is 16550 and 16750 compatible, but has extra features that require communicating with an 
additional 8 registers per channel. For instance, it is necessary to set the “Auto RTS” function. (EXAR 
refers to this function as “Auto RS485" in their literature). The required writing to the UART is done 
automatically when the card is rebooted. 
  
In order to utilize standard software that communicates only with the first 8 registers of each channel, 
addresses are remapped on the card. 
  
The 8 UARTS occupy the first 64 addresses.  
  
The interrupt status register is located at base + 40h. 
 
Baud Rates
On the card, the UART clock frequency is 1.8432 MHz. Below is a table of popular divisor frequencies. 
 
Baud Rate  Divisor x1
Divisor x8 
Max Diff. Cable Length* 
921600 - 
250 
ft 
460800 - 
550 
ft 
230400 - 
1400 
ft 
153600 - 
2500 
ft 
115200 1 
3000 
ft 
57600 2 
16 
4000 
ft 
38400 3 
24 
4000 
ft 
28800 4 
32 
4000 
ft 
19200 6 
48 
4000 
ft 
14400 8 
64 
4000 
ft 
9600 
12 
96 – Most Common 4000 ft 
4800 24  192 
4000 
ft 
2400 48  384 
4000 
ft 
1200 96  768 
4000 
ft 
  
*These are theoretical maximums based on typical conditions and good quality cables, based on the EIA 
485 and EIA 422 standard for balanced differential drivers. 
Table 5-1:
 Baud Rate Divisor Values
Manual LPCI-COM-8SM 
18