Справочник Пользователя для Mitsubishi Electronics DX-TL1600EM

Скачать
Страница из 86
18
••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••••
Connections
■ 
Connecting to CCTV camera, monitor, sensor, the electric power supply and ferrite core
MONITOR
To
VIDEO OUT
or
S(Y/C) OUT
terminal
One of either codes should
be connected.
To CAMERA IN 1
terminal
CAMERA #1
To S(Y/C) IN
terminal
To GND
terminal
To ALARM IN terminal
corresponds to the 
CAMERA #.
Up to 16 cameras
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
CAMERA IN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
CAMERA OUT
VIDEO OUT
Y/C
CLOCK ADJ
REC
POWER ON
POWER OFF
ALARM OUT
MODE OUT
CALL OUT
CALL OUT GND
GND
GND
DC 5V OUT 
MAX 30mA
GND
RS-232C
ETHERNET
RESET
ON
SCSI
SCSI
TERMINATION
GND
GND
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
ALARM IN
OFF
Processing the connecting line
Connection on the ALARM IN side 
Compatible power lines
ø
0.32 ~ 
ø
0.65 mm (AWG 28 ~ 22)
Connection on the I / O side
Compatible power lines
ø
0.4 ~ 
ø
1.2 mm (AWG 26 ~ 16)
Cut the designated area from the electric 
wire’s outer covering (vinyl portion).
10~12mm
5~7mm
To ETHERNET
Socket
POWER CORD
for U.K
for the Continent
Ferrite core
SENSOR #1
 Turning ON/OFF this Unit by peripheral source
By using POWER ON/POWER OFF terminal on (I/O termi-
nals) , it is possible to turn on/off this unit externally.  This
function is related to the output of DC 5V OUT terminal.
The relationship between POWER ON/POWER OFF termi-
nal, DC 5V OUT terminal and turning on/off this unit is shown
in the diagram.  Please use suitable peripheral devices to con-
nect with this unit.
Using POWER ON terminal
POWER ON
terminal
ground
0V
power off
Unit's
power
DC 5V OUT
(4.5-5.5V 
Max.30mA) 
DC 5V
 
power on
power on
shut down
boot
up
Using POWER OFF terminal
POWER OFF
terminal
0V
power off
ground
shut down
power on
Unit's
power
DC 5V OUT
(4.5-5.5V 
Max.30mA) 
DC 5V 
■ 
Attaching the ferrite core
To avoid interference from the cables connected to the unit
against other apparatus, attach the ferrite core to all ca-
bles connected to the control terminal cables and ALARM
IN terminals (GND terminals) as indicated and place it as
close to the unit as possible. Use the ferrite core to bundle
together all of the cables connected to each terminal.
Tie cables at the band    
To the other apparatus