5.  Base Specifications Parameters 
 
 
15 
5.  Base Specifications Parameters 
After setting up the parameter (PR) listed in the table, turn off the NC power. To validate the 
parameter, turn on the power again. 
 
# Items 
Details 
Setting range (unit)
1001 
(PR) 
SYS_ON 
Part system 
validation 
setup 
Specify the presence of the PLC axes and the 1st to 
7th part systems with 1 or 0. 
0:  Not used  
1:  Used 
1002 
(PR) 
axisno Number 
of 
axes 
Set No. of axes in each part system and the No. of PLC 
axes. 
Set so that the total of the NC axes and PLC axes is 
less than the maximum number of controllable axes. 
0 to 14 
1003 
(PR) 
iunit Input 
setup 
unit 
Specify the input setting value for each part system 
and the PLC axis. The parameter units will follow this 
specification. 
B:   1 
µm 
C:   0.1 
µm 
1013  axname  Axis name 
Specify each axis’ name address with an alphabetic 
character. 
Use the characters X‚ Y‚ Z‚ U‚ V‚ W‚ A‚ B or C. 
Do not specify the same address in one part system.  
The same address can be specified as the other part 
system.  
The PLC address does not need to be set. (The axis 
name is displayed as 1 and 2.) 
Axis addresses 
such as X, Y, Z, U, 
V, W, A, B, and C 
1014 incax 
Increment 
command 
axis name 
When specifying the program movement rate’s 
absolute or incremental method with an address‚ 
specify the incremental command axis name address 
with an alphabetic character.  
The address that can be used is the same as "#1013 
axname".  
Specify an address that is different from that #1013.  
Setting is not required if absolute/incremental command 
with addresses is not performed ("#1076 Abslnc" = 0). 
 
1015 
(PR) 
cunit Command 
unit 
Specify the minimum unit of the program movement 
amount.  
cunit 
Movement amount for movement command 1 
      10:  0.001  mm (    1 
µm)  
    100:  0.01  mm (  10 
µm)  
  1000:  0.1 
mm (100 
µm)  
10000: 1.0 
mm  
If there is a decimal point in the movement command‚ 
the decimal point position will be handled as 1mm 
regardless of this setting. 
10 
µm 
100 
10 
µm 
1000 
100 
µm 
10000 1 
mm 
 
 
1016 
(PR) 
iout 
Inch output 
Specify whether the machine system (ball screw pitch‚ 
position detection unit) is an inch unit system or metric 
unit system. 
0:  Metric unit 
     system 
1:  Inch unit system