5.  Base Specifications Parameters 
 
 
17 
 
# Items 
Details 
Setting range (unit)
1025 l_plane  Initial plane 
selection 
Specify the plane to be selected when the power is 
turned on or reset. 
When 0 is specified, 1 is assumed (X-Y plane). 
1
:  X-Y plane (G17 
command state) 
2:  Z-X plane (G18 
command state) 
3:  Y-Z plane (G19 
command state)
 
1026 
1027 
1028 
base_l 
base_J 
base_K 
Base axis I 
Base axis J 
Base axis K 
Specify the basic axis address that composes the 
plane. 
Specify the axis address set in “#1013 axname”. 
Set the axis name even when there is no need to 
configure a plane, such as the case of 2-axis 
specifications. 
Normally‚ when X‚ Y and Z are specified respectively 
for base_l‚_J‚_K‚ the following relation will be 
established: 
G17: X-Y 
G18: Z-X 
G19: Y-Z 
Specify the desired address to set an axis address 
other than the above. 
Control axis 
addresses such as 
X, Y, and Z 
1029  aux_I 
Flat axis I 
If there is an axis parallel to "#1026 base_l"‚ specify 
that axis address. 
Control axis 
addresses such as 
X, Y, and Z 
1030  aux_J 
Flat axis J 
If there is an axis parallel to "#1027 base_J"‚ specify 
that axis address. 
Control axis 
addresses such as 
X, Y, and Z 
1031  aux_K 
Flat axis K 
If there is an axis parallel to "#1028 base_K"‚ specify 
that axis address. 
Control axis 
addresses such as 
X, Y, and Z