8.  Spindle Parameters 
8.5  Supplement 
267 
(2) Setting the output data 
 
Input the No. of the data to be output to each D/A output channel. 
# No. Abbrev 
Parameter 
name 
3453 
SP253 
DA1NO 
D/A output channel 1 data No. 
3454 
SP254 
DA2NO 
D/A output channel 2 data No. 
 
No. 
Output data 
Original data unit 
Standard setting value 
for output scale  
(Setting values in 
SP255, SP256) 
Standard 
output unit 
Output 
cycle 
ch1: Speed meter 
output 
10V=max. speed 
(0=0V) 
0 Depends 
on 
the max. 
speed 
3.55ms
ch2: Load meter 
output 
10V=120% load (0=0V) 0 
Rated 
12%/V 
3.55ms
1 – 
 
 
 
 
Current command  Rated 100% = 4096 
Rated 
20%/V 
3.55ms
Current feedback  Rated 100% = 4096 
Rated 
20%/V 
3.55ms
4 Speed 
feedback  r/min 
13 
500rpm/V  3.55ms
5 – 
 
 
 
 
6  Position droop 
1° = (64000/65536) 
671 
10°/V 
888µs 
7 – 
 
 
 
 
Feedrate (F
∆T) 
1° = (64000/65536) 
629 
(When communicating 
by 3.5ms) 
500rpm/V 888µs 
9 – 
 
 
 
 
10  Position command  1° = (64000/65536) 19 
(18.64) 
360°/V  888µs 
11 – 
 
 
 
 
12  Position feedback  1° = (64000/65536) 19 
(18.64) 
360°/V  888µs 
13 – 
 
 
 
 
80  Control input 1 
81  Control input 2 
82  Control input 3 
83  Control input 4 
HEX Bit 
correspondence 
3.55ms
84  Control output 1 
85  Control output 2 
86  Control output 3 
87  Control output 4 
HEX Bit 
correspondence 
3.55ms
125 
Saw-tooth wave 
test output 
 0 
(256) 
Cycle 
227.5ms 
444µs 
126 
Rectangular wave 
test output 
 
0 (256) 
Cycle 1.7ms  444µs 
127 
2.5V(data0) test 
output 
 0 
(256) 
– 
444µs