8.  Spindle Parameters 
8.5  Supplement 
268 
(3) Setting the output scale 
 
# No. Abbrev 
Parameter 
name 
3455 
SP255 
DA1MPY 
D/A output channel 1 magnification 
3456 
SP256 
DA2MPY 
D/A output channel 2 magnification 
 
Usually, the standard setting value is set for the output scale (SV063, SV 064). When “0” is set, the 
output will be made as well as when “256” is set. 
 
SP255
10 [V] 
DATA x 
256 
256 (8bit)
+
5 [V] (offset)
=
Output voltage [V] 
 
(Example) When outputting the position droop with 10°/V. 
 
640000 671  10 
65536 
256 
256 
+
5 = 5.999 