7. SYSTEM CHECKING FROM PERIPHERAL DEVICE 
 
HELPFUL CORRECTIVE ACTIONS
 
 
Take the following corrective actions when AD75P checking connect cannot be 
completed properly. 
 
Status Corrective 
Action 
AD75P checking connect 
cannot start 
Check the connection of cables with the AD75P. 
Using the optional function (refer to Section 12.5), check whether COM setting is correct. 
Check that the servo amplifier is powered. 
Drive unit ready is OFF 
Check the connection of the external I/O signal connector. 
Check the connection of the external I/O signal connector. 
Upper/lower limit is OFF 
Check for contact of the upper/lower limit switch. 
JOG operation cannot be 
performed. 
Check that JOG speed setting is not "0". 
Error/warning occurred 
Check the error/warning code using [Help], and check and remove the cause.