Справочник Пользователя для Mitsubishi Electronics QD75D

Скачать
Страница из 768
8 - 10
MELSEC-Q
8   OPR CONTROL
(3) If the "
Pr.49
 OPR dwell time" elapses before the stop at the stopper, the workpiece
will stop at that position, and that position will be regarded as the OP.
At this time, an error will not occur.
Pr. 46 OPR speed 
ON
ON
OFF
OFF
ON
0
V
ON
t
Pr. 47 Creep speed
Torque limit
Near-point dog OFF 
Valid torque limit range 
Dwell time measurement 
Time out of dwell time 
Machine OPR start 
(Positioning start signal)
Deviation counter clear output 
Md.26 Axis operation status
OPR request flag
  [ Md.31 Status : b3]
OPR complete flag
  [ Md.31 Status : b4]
Md.34 Movement amount 
after near-point dog ON
Md.20 Current feed value
Md.21 Machine feed value
Standing by
In OPR
Inconsistent 
Inconsistent 
Value the machine moved is stored
Standing by
OP address 
OFF
Stops at stopper
Pr.55  Deviation counter clear signal
           output time
Fig. 8.6 Operation when the dwell time elapses before the stop at the stopper
(4) Machine OPR started while the near-point dog is ON will start at the "
Pr.47
 Creep
speed".
(5) When a machine OPR is stopped with the stop signal, perform a machine OPR again.
If the restart command is turned ON after a stop with the stop signal, an error "OPR
restart not possible" (error code: 209) occurs.