10   HIGH-LEVEL POSITIONING CONTROL
10.3.4 Wait start
In a "wait start", the "condition data" conditional judgment designated in "
Da.14
Parameter" is carried out for the positioning data set in "
Da.12
 Start data No.". If the
conditions have been established, the " block start data" is executed. If the conditions
have not been established, the control stops (waits) until the conditions are
established.
Section [2] shows a control example where the " block start data" and "positioning
data" are set as shown in section [1].
[1]   Setting examples
(1) Block start data setting example
Axis 1 block
start data
Da.11
Shape
Da.12
Start data No.
Da.13
Special start
instruction
Da.14
Parameter
1st point
1: Continue
1
2: Wait start
3
2nd point
1: Continue
10
0: Block start
3rd point
0: End
50
0: Block start

 The "condition data Nos." have been set in " Da.14  Parameter".
(2)   Positioning data setting example
Axis 1 position-
ing data No.
Da.1
Operation pattern
1
01: Continuous positioning control
2
01: Continuous positioning control
3
00: Positioning complete
10
11: Continuous path control
11
11: Continuous path control
12
00: Positioning complete
50
00: Positioning complete
[2]   Control examples
The following shows the control executed when the " block start data" of the 1st
point of axis 1 is set as shown in section [1] and started.
<1> The conditional judgment set in "condition data No. 3" is carried out before
execution of the axis 1 "positioning data No. 1".
Conditions established 
 Execute positioning data No. 1, 2, and 3 
Go to <2>.
Conditions not established 
 Control stops (waits) until conditions are
established   Go to <1>.
<2> Execute the axis 1 "positioning data No. 10, 11, 12, and 50" and stop the
control.