10   HIGH-LEVEL POSITIONING CONTROL
10.3.6 Repeated start (FOR loop)
In a "repeated start (FOR loop)", the data between the " block start data" in which "4:
FOR loop" is set in "
Da.13
 Special start instruction" and the "block start data" in
which "6: NEXT start" is set in "
Da.13
 Special start instruction " is repeatedly
executed for the No. of times set in "
Da.14
 Parameter". An endless loop will result if
the No. of repetitions is set to "0".
(The No. of repetitions is set in "
Da.14
 Parameter" of the " block start data" in which
"4: FOR loop" is set in "
Da.13
 Special start instruction".)
Section [2] shows a control example where the " block start data" and "positioning
data" are set as shown in section [1].
[1]   Setting examples
(1)   Block start data setting example
Axis 1 block
start data
Da.11
Shape
Da.12
Start data No.
Da.13
Special start
instruction
Da.14
Parameter
1st point
1: Continue
1
4: FOR loop
2
2nd point
1: Continue
10
0: Block start
3rd point
0: End
50
6: NEXT start

 The "condition data Nos." have been set in " Da.14  Parameter".
(2)   Positioning data setting example
Axis 1 position-
ing data No.
Da.1
Operation pattern
1
01: Continuous positioning control
2
01: Continuous positioning control
3
00: Positioning complete
10
11: Continuous path control
11
00: Positioning complete
50
01: Continuous positioning control
51
00: Positioning complete
[2]   Control examples
The following shows the control executed when the " block start data" of the 1st
point of axis 1 is set as shown in section [1] and started.
<1> Execute the axis 1 "positioning data No. 1, 2, 3, 10, 11, 50, and 51".
<2> Return to the axis 1 "1st point block start data". Again execute the axis 1
"positioning data No. 1, 2, 3, 10, 11, 50 and 51", and then stop the control.
(Repeat for the No. of times (2 times) set in 
Da.14
.)