Справочник Пользователя для Mitsubishi Electronics FX2NC

Скачать
Страница из 382
FX Series Programmable Controlers
Applied Instructions 5
5-42
5.5
Data Operation - Functions 40 to 49
Contents:
Page
ZRST - 
Zone Reset 
FNC 40 
5-43
DECO - 
Decode 
FNC 41 
5-43
ENCO - 
Encode 
FNC 42 
5-44
SUM - 
The Sum Of Active Bits 
FNC 43 
5-45
BON - 
Check Specified Bit Status 
FNC 44 
5-45
MEAN - 
Mean 
FNC 45 
5-46
ANS - 
(Timed) Annunciator Set 
FNC 46 
5-47
ANR - 
Annunciator Reset 
FNC 47 
5-47
SQR - 
Square Root 
FNC 48 
5-48
FLT - 
Float, (Floating Point) 
FNC 49 
5-49
Symbols list:
D - Destination device.
S - Source device.
m, n- Number of active devices, bits or an operational constant.
Additional numeric suffixes will be attached if there are more than one operand with the same
function e.g. D
1
, S
or for lists/tabled devices D
3+0, 
S
+9 
etc.
MSB - Most Significant Bit, sometimes used to indicate the mathematical sign of a number, i.e.
positive = 0, and negative = 1.
LSB - Least Significant Bit.
Instruction modifications:
 
An instruction operating in 16 bit mode, where 
 identifies the instruction
mnemonic.
P -  A 16 bit mode instruction modified to use pulse (single) operation.
D
 
-  An instruction modified to operate in 32 bit operation.
D
P -  A 32 bit mode instruction modified to use pulse (single) operation.
 
- A repetitive instruction which will change the destination value on every scan unless
modified by the pulse function.
 
- An operand which cannot be indexed, i.e. The addition of V or Z is either invalid or will
have no effect to the value of the operand.