6. TROUBLESHOOTING 
6 -  1 
 
6. TROUBLESHOOTING 
POINT  
Alarms and warnings are basically the same as those of MR-J3- B servo 
amplifier. This chapter describes the contents different from those of MR-J3- B 
servo amplifier. 
As soon as an alarm occurs, make the servo-off status and interrupt the main 
circuit power. 
 
 
If an alarm has occurred, refer to this chapter and remove its cause. 
 
6.1 Alarms and warning list 
When a fault occurs during operation, the corresponding alarm or warning is displayed. Refer to section 6.2 of 
this manual and section 8.2 of the MR-J3- B Servo Amplifier Instruction Manual at an alarm occurrence and 
section 6.3 of this manual and section 8.3 of the MR-J3- B Servo Amplifier Instruction Manual at a warning 
occurrence, and then take the appropriate action. When an alarm occurs, the ALM turns off. 
After its cause has been removed, the alarm can be deactivated in any of the methods marked 
  in the alarm 
deactivation column. The alarm is automatically canceled after removing the cause of occurrence. 
 
Alarm deactivation 
 
Display
Name 
92 
Battery cable disconnection warning
 
Display Name  Power 
off on 
Error 
reset 
CPU 
reset 
96 
Home position setting error 
10 Undervoltage 
 
 
 9F 
Battery 
warning 
12 
Memory error 1 (RAM) 
 
 
 
E0 
Excessive regeneration warning 
13 Clock 
error 
 
 
 
E1 
Overload warning 1 
15 
Memory error 2 (EEP-ROM) 
 
 
 
E2 
Direct drive motor overheat warning
16 
Encoder error 1 
 
 
 
E3 
Absolute position counter warning 
17 Board 
error 
    
E4 
Parameter 
warning 
19 
Memory error 3 (Flash-ROM) 
 
 
 
E6 
Servo forced stop warning 
1A 
Motor combination error 
 
 
 
E7 
Controller forced stop warning 
1F 
Encoder combination error 
 
 
 
Cooling fan speed reduction 
20 
Encoder error 2 
 
 
 
E8 
warning 
21 
Encoder error 3 
 
 
 
E9 
Main circuit off warning 
24 
Main circuit error 
 
 
 
EC 
Overload warning 2 
25 
Absolute position erase 
 
 
 
Warni
ngs
 
ED 
Output watt excess warning 
27 
Initial magnetic pole detection error 
 
 
 
 
 
 
2B 
Encoder counter error 
 
 
 
 
 
 
30 
Regenerative error 
(Note 1)
(Note 1)
(Note 1)
 
 
 
31 Overspeed 
 
 
 
 
 
 
32 Overcurrent 
 
 
 
 
 
 
33 Overvoltage 
 
 
 
 
 
 
34 
Receive error 1 
 (Note 
2)
 
 
 
 
35 
Command frequency alarm 
 
 
 
 
 
 
36 
Receive error 2 
 
 
 
 
 
 
37 Parameter 
error 
 
 
 
 
 
 
42 
Servo control error 
 (Note 
3)
(Note 3)
 
 
 
45 
Main circuit device overheat 
(Note 1)
(Note 1)
(Note 1)
 
 
 
46 
Direct drive motor overheat 
(Note 1)
(Note 1)
(Note 1)
 
 
 
47 
Cooling fan alarm 
 
 
 
 
 
 
50 
Overload 1 
(Note 1)
(Note 1)
(Note 1)
 
 
 
51 
Overload 2 
(Note 1)
(Note 1)
(Note 1)
 
 
 
52 Error 
excessive 
 
 
 
 
 
 
8A 
USB communication time-out error 
 
 
 
 
 
 
8E 
USB communication error 
 
 
 
 
 
 
Ala
rms 
888 Watchdog 
 
 
 
 
 
 
Note 1. Deactivate the alarm about 30 minutes of cooling time after removing the cause of occurrence. 
          2. In some controller communication status, the alarm factor may not be removed. 
     3. Set parameter No.PS04 to "1
" to deactivate.