Справочник Пользователя для Mitsubishi Electronics MR-J3-B-RJ080W

Скачать
Страница из 144
6. TROUBLESHOOTING 
6 -  6 
 
Display Name 
Definition 
Cause 
Action 
52 
Error excessive  Refer to chapter 8 of the MR-J3- B Servo Amplifier Instruction Manual. 
8A USB 
communication 
time-out error 
 
 
 
8E USB 
communication 
error 
 
 
 
888 Watchdog 
 
 
 
 
6.3 Remedies for warnings 
CAUTION 
If an absolute position counter warning (E3) occurred, always make home position 
setting again. Otherwise, it may cause an unexpected operation. 
 
 
POINT  
When any of the following alarms has occurred, do not resume operation by 
switching power of the servo amplifier off/on repeatedly. The servo amplifier and 
direct drive motor may become faulty. If the power of the servo amplifier is 
switched off/on during the alarms, allow more than 30 minutes for cooling before 
resuming operation. 
Excessive regenerative warning (E0) 
Overload warning 1 (E1) 
Direct drive motor overheat (E2) 
 
 
If E6, E7 or E9 occurs, the servo-off status is established. If any other warning occurs, operation can be 
continued but an alarm may take place or proper operation may not be performed. 
Remove the cause of warning according to this section. Use MR Configurator to refer to a factor of warning 
occurrence. 
 
Display Name 
Definition 
Cause 
Action 
92 
1. Battery cable is open. 
Repair the cable or replace the battery. 
 
Battery cable 
disconnection 
warning 
Absolute position 
detection system 
battery voltage is low. 
2. Battery voltage supplied from the 
servo amplifier to the encoder fell to 
about 3V or less. 
(Detected with the encoder) 
Replace the battery. 
 
 
 
3. An absolute position storage unit is 
not connected. 
Connect the absolute position storage unit. 
96 Home 
position 
setting warning 
Refer to chapter 8 of the MR-J3- B Servo Amplifier Instruction Manual. 
9F 
1. Battery voltage fell to 3.2V or less. 
(Detected with the servo amplifier) 
 
2. Battery deteriorated and its voltage 
fell. 
(Detected with the encoder) 
Replace the battery. 
 
Battery warning  Voltage of battery for 
absolute position 
detection system 
reduced. 
3. An absolute position storage unit is 
not connected. 
Connect the absolute position storage unit.