Справочник Пользователя для Mitsubishi Electronics MR-J3-B-RJ080W

Скачать
Страница из 144
6. TROUBLESHOOTING 
6 -  4 
 
Display Name 
Definition 
Cause 
Action 
30 Regenerative 
error 
Refer to chapter 8 of the MR-J3- B Servo Amplifier Instruction Manual. 
31 Overspeed   
 
 
32 Overcurrent   
 
 
33 Overvoltage   
 
 
34 
Receive error 1   
 
 
35 Command 
frequency alarm 
 
 
 
36 
Receive error 2   
 
 
37 Parameter 
error 
 
 
 
42 Servo 
control 
error 
Servo control error 
occurred. 
1. Initial magnetic pole detection has 
not been performed. 
Perform initial magnetic pole detection. 
 
 
 
2. The position deviation exceeded the 
detection level. 
Check the operation condition. 
Check the setting of parameter No.PS05 
(Servo control position deviation error 
detection level) as required. 
 
 
 
3. The speed deviation exceeded the 
detection level. 
Check the operation condition. 
Check the setting of parameter No.PS06 
(Servo control speed deviation error 
detection level) as required. 
 
 
 
4. Torque deviation exceeded the 
detection level. 
Check the operation condition. 
Check the parameter No.PS07 setting 
(Servo control torque deviation error 
detection level) as necessary. 
 
 
 
5. Wrong connection of direct drive 
motor. 
Servo amplifier’s power supply 
output (U, V, and W) do not match 
with direct drive motor’s power 
supply input (U, V, and W). 
Connect correctly. 
45 Main 
circuit 
device overheat 
Refer to chapter 8 of the MR-J3- B Servo Amplifier Instruction Manual. 
46 
1. Ambient temperature of direct drive 
motor is over 40  (104 ). 
Check environment so that ambient 
temperature is 0 to 40   (32 to 104 ). 
 
Direct drive 
motor overheat 
Direct drive motor 
temperature rose. 
(Detected by 
thermistor) 
2. Direct drive motor is overloaded. 
1. Reduce load. 
2. Check operation pattern. 
3. Replace direct drive motor that provides 
larger output. 
 
 
 
3. Thermistor in direct drive motor is 
faulty. 
Replace the direct drive motor. 
 
 
 
4. Thermistor wire faulty. 
(Breakage or short-circuit) 
Repair or replace the encoder cable. 
47 Cooling 
fan 
alarm 
Refer to chapter 8 of the MR-J3- B Servo Amplifier Instruction Manual.