Справочник Пользователя для Mitsubishi Electronics MR-J3-B-RJ080W

Скачать
Страница из 144
8. CHARACTERISTICS 
8 -  3 
 
8.2 Dynamic brake characteristics 
POINT  
Dynamic brake operates at occurrence of alarm, servo forced stop warning (E6), 
and controller forced stop warning (E7), and when power is turned off. Do not use 
dynamic brake to stop in a normal operation as it is the function to stop in 
emergency. 
For a machine operating at the recommended load to motor inertia ratio or less, the 
estimated number of usage times of the dynamic brake is 1000 times while the 
machine decelerates from the rated speed to a stop once in 10 minutes. 
Be sure to make forced stop (EM1) valid after direct drive motor stops when using 
forced stop (EM1) frequently in other than emergency. 
 
 
8.2.1 Dynamic brake operation 
(1)  Calculation of coasting distance 
Fig. 8.2 shows the pattern in which the direct drive motor comes to a stop when the dynamic brake is 
operated. Use equation 8.1 to calculate an approximate coasting distance to a stop. The dynamic brake 
time constant 
  varies with the direct drive motor and machine operation speeds. (Refer to (2) of this 
section.) 
V
0
Dynamic brake time constant 
OFF
ON
Machine speed
t
e
Time
Forced stop (EM1)
 
Fig. 8.2 Dynamic brake operation diagram 
 
L
max
60
V
0
J
L
J
M
t
e
1
································································································································ (8.1)
 
 
L
max
 
V
O
 
J
M
 
J
L
 
 
t
e
 
: Maximum coasting distance·············································································································· [mm][in]
: Machine rapid feed rate······································································································· [mm/min][in/min]
: Direct drive motor inertial moment ··············································································[×10
-4
 kg m
2
][oz in
2
]
: Load inertia moment converted into equivalent value on direct drive motor rotor ·····[×10
-4
 kg m
2
][oz in
2
]
: Dynamic brake time constant······················································································································[s]
: Delay time of control section ·······················································································································[s]
There is internal relay delay time of about 10ms.