Справочник Пользователя для Mitsubishi Electronics MR-J3-B-RJ080W
4. OPERATION AND FUNCTIONS
4 - 11
4.3.2 Servo system controller setting
(1) Setting instructions
When using the direct drive servo, set it as described in this section. For other servo parameters and
positioning control parameters, set them in the same method as that of MR-J3- B servo amplifier.
The following servo parameters will be valid by turning the power of servo amplifier off once and then turning
it on again after writing to the servo amplifier from the controller.
positioning control parameters, set them in the same method as that of MR-J3- B servo amplifier.
The following servo parameters will be valid by turning the power of servo amplifier off once and then turning
it on again after writing to the servo amplifier from the controller.
Setting description
Setting Item
Motion controller
Q17 DCPU/Q170MCPU
(Note 3)
Positioning module
LD77MH /QD74MH /
QD75MH
Amplifier setting
MR-J3-B DD
MR-J3-DD (Note 4)
Motor setting
Automatic setting
No.
(Note 1)
Symbol
Name
Initial
value
value
PA01
For manufacturer setting (Note 2)
0060h
PC01 *ERZ Error excessive alarm level
3
PC03 *ENRS Encoder output pulses selection
0000h
PD03
For manufacturer setting (Note 2)
0020h
PD04
0021h
PS01 **LIT1 Special function selection 1
0001h
PS04 *LIT2 Special function selection 2
0003h
PS05
LB1
Servo control position deviation error
detection level
detection level
9
PS06
LB2
Servo control speed deviation error
detection level
detection level
100
PS07
LB3
Servo control torque deviation error
detection level
detection level
100
PS08 *LIT3 Special function selection 3
0010h
PS09 LPWM Magnetic pole detection voltage level
30
PS10
For manufacturer setting (Note 2)
0005h
PS11
0064h
PS12
01F4h
PS17 LTSTS Minute position detection method function
selection
0000h
Servo
parameters
parameters
PS18
IDLV
Minute position detection method
identification signal amplitude
identification signal amplitude
0
Set as necessary.
When using QD74MH
or QD75MH , set it with
sequence program.
It is necessary to set the
initial values of these
parameters at the startup
of direct drive servo.
Refer to (2) and (3) in this
section.
When using LD77MH ,
set it with GX
Configurator-QP
(SW2D5C-QD75P-E) as
necessary.
or QD75MH , set it with
sequence program.
It is necessary to set the
initial values of these
parameters at the startup
of direct drive servo.
Refer to (2) and (3) in this
section.
When using LD77MH ,
set it with GX
Configurator-QP
(SW2D5C-QD75P-E) as
necessary.
Note 1. The parameters having * before the symbol will be valid in the following conditions.
* : Turn the power of servo amplifier off once after the setting and then turn it on again, or execute the controller reset.
** : Turn the power of servo amplifier off once after the setting, and then turn it on again.
** : Turn the power of servo amplifier off once after the setting, and then turn it on again.
2. For the LD77MH /QD74MH /QD75MH , make sure to set the initial value.
3. Pay attention on the followings.
3. Pay attention on the followings.
If the parameter (servo parameter) of servo amplifier has been changed, it automatically reads the servo parameter and stores in
the buffer memory of LD77MH /QD74MH /QD75MH . However, it does not reflect to the flash ROM.
When turning off, resetting the power of LD77MH /QD74MH /QD75MH or turning off the control circuit power supply of
servo amplifier right after changing the servo parameter, the servo parameter may not reflect to the buffer memory of
LD77MH /QD74MH /QD75MH . In such a case, change it again.
the buffer memory of LD77MH /QD74MH /QD75MH . However, it does not reflect to the flash ROM.
When turning off, resetting the power of LD77MH /QD74MH /QD75MH or turning off the control circuit power supply of
servo amplifier right after changing the servo parameter, the servo parameter may not reflect to the buffer memory of
LD77MH /QD74MH /QD75MH . In such a case, change it again.
4. Set QD74MH and QD75MH with sequence program. (Refer to (2) of this section.)