Справочник Пользователя для Mitsubishi Electronics MR-J3-B-RJ080W

Скачать
Страница из 144
4. OPERATION AND FUNCTIONS 
4 -  11 
 
4.3.2 Servo system controller setting 
(1) Setting instructions 
When using the direct drive servo, set it as described in this section. For other servo parameters and 
positioning control parameters, set them in the same method as that of MR-J3- B servo amplifier. 
The following servo parameters will be valid by turning the power of servo amplifier off once and then turning 
it on again after writing to the servo amplifier from the controller. 
 
Setting description 
Setting Item 
Motion controller 
Q17 DCPU/Q170MCPU 
(Note 3) 
Positioning module 
LD77MH /QD74MH /
QD75MH  
Amplifier setting 
 
MR-J3-B DD 
MR-J3-DD (Note 4) 
Motor setting 
 
Automatic setting 
 
No. 
(Note 1) 
Symbol 
Name 
Initial 
value 
PA01 
 
For manufacturer setting (Note 2) 
0060h 
PC01  *ERZ  Error excessive alarm level 
PC03  *ENRS  Encoder output pulses selection   
0000h 
PD03 
For manufacturer setting (Note 2) 
0020h 
PD04 
 
 0021h 
PS01  **LIT1  Special function selection 1 
0001h 
PS04  *LIT2  Special function selection 2 
0003h 
PS05 
LB1 
Servo control position deviation error 
detection level 
PS06 
LB2 
Servo control speed deviation error 
detection level 
100 
PS07 
LB3 
Servo control torque deviation error 
detection level 
100 
PS08  *LIT3  Special function selection 3 
0010h 
PS09  LPWM  Magnetic pole detection voltage level 
30 
PS10 
For manufacturer setting (Note 2) 
0005h 
PS11  
0064h 
PS12 
 
 01F4h
PS17  LTSTS  Minute position detection method function 
selection 
0000h 
Servo 
parameters 
PS18 
IDLV 
Minute position detection method 
identification signal amplitude 
Set as necessary. 
When using QD74MH  
or QD75MH , set it with 
sequence program. 
It is necessary to set the 
initial values of these 
parameters at the startup 
of direct drive servo. 
Refer to (2) and (3) in this 
section. 
When using LD77MH , 
set it with GX 
Configurator-QP 
(SW2D5C-QD75P-E) as 
necessary. 
Note 1. The parameters having * before the symbol will be valid in the following conditions. 
* : Turn the power of servo amplifier off once after the setting and then turn it on again, or execute the controller reset. 
** : Turn the power of servo amplifier off once after the setting, and then turn it on again. 
     2. For the LD77MH /QD74MH /QD75MH , make sure to set the initial value. 
     3. Pay attention on the followings. 
If the parameter (servo parameter) of servo amplifier has been changed, it automatically reads the servo parameter and stores in 
the buffer memory of LD77MH /QD74MH /QD75MH . However, it does not reflect to the flash ROM. 
When turning off, resetting the power of LD77MH /QD74MH /QD75MH   or turning off the control circuit power supply of 
servo amplifier right after changing the servo parameter, the servo parameter may not reflect to the buffer memory of 
LD77MH /QD74MH /QD75MH . In such a case, change it again. 
          4. Set QD74MH  and QD75MH   with sequence program. (Refer to (2) of this section.)