Справочник Пользователя для Mitsubishi Electronics FR-A700

Скачать
Страница из 523
101
4
(1) Torque limit block diagram
(2) Selection of torque limit input method (Pr. 810
⋅ Set Pr. 810 Torque limit input method selection to select the method to limit output torque during speed control.
Torque limit by parameter setting is initially set.
(3) Torque limit level by parameter setting (Pr. 810 = "0"
Pr. 812 to Pr. 814 ) 
(4) Torque limit level by analog input (terminal 1, 4) (Pr. 810 = "1", Pr. 858Pr. 868 
Parameter 
Number
Setting 
Range
Torque Limit Input 
Method
Description
810
0 (initial 
value)
Internal torque limit
Parameter-set torque limit operation is performed.
Changing the torque limit parameter value by communication enables torque limit 
to be input by communication. 
1
External torque limit Torque limit using analog voltage (current) to terminal 1 or terminal 4 is enabled. 
⋅ With the initial value, limit is made ON all quadrants on the
Pr.  22 Stall prevention operation level (torque limit level) .
⋅ When you want to set the level on a quadrant basis, set the
torque limit level in Pr. 812 Torque limit level (regeneration)Pr.
813 Torque limit level (3rd quadrant)
Pr. 814 Torque limit level
(4th quadrant)
.
When "9999" is set, Pr. 22 is the torque limit level.
⋅ With the upper limit of torque limit as set in Pr. 22, the analog input from terminal 1 input is used as the torque limit
value within the Pr. 22 setting range.
⋅ When torque limit value is input to terminal 1, set "4" in Pr. 868 Terminal 1 function assignment. When torque limit value
is input from terminal 4, set "4" in Pr. 858 Terminal 4 function assignment.
⋅ When Pr. 858="4" and Pr. 868="2," torque is limited by analog input to terminal 1 for regeneration and to terminal 4 for
driving. 
⋅ Torque limit by analog input can be calibrated using calibration parameter C16 (Pr. 919) to C19 (Pr. 920), C38 (Pr. 932) to
C41 (Pr. 933) (Refer to page 300)
*
Analog input (terminal 1, 4) or internal torque control (Pr. 22 etc.) whichever is smaller
Torque limit
<Vector control>
 
Speed control
 
Speed command +
-
 
Iq current control
 
IM
 
Encoder
quad1
( Pr. 22)
quad4
( Pr. 814)
( Pr. 813)
quad2
( Pr. 812)
Reverse 
rotation
Forward 
rotation
Torque limit
Speed
Reverse 
driving
Reverse 
regeneration
Rated speed
quad3
+
-
Forward 
regeneration
Forward 
driving
*
*
*
*
quad1
( Pr. 22)
quad4
( Pr. 814)
( Pr. 813)
quad2
( Pr. 812)
Reverse 
rotation
Forward 
rotation
Torque limit
Speed
Reverse 
driving
Reverse 
regeneration
Rated speed
quad3
+
-
Forward 
regeneration
Forward 
driving
When Pr.858=4, Pr.868=2
quad1
quad4
quad2
Reverse rotation
Forward rotation
Torque limit
Rated speed
+
-
Terminal 1 input or 
internal torque limit
(Pr.22 etc.) whichever
is smaller
Speed
quad3
Reverse 
regeneration
Reverse 
driving
Forward 
driving
Forward 
regeneration
Terminal 4 input or 
internal torque limit
(Pr.22 etc.) whichever
is smaller
Terminal 4 input or 
internal torque limit
(Pr.22 etc.) whichever
is smaller
Terminal 1 input or 
internal torque limit
(Pr.22 etc.) whichever
is smaller