4.4.4
To perform high accuracy/fast response operation (gain adjustment of Real
sensorless vector control and vector control) (Pr. 818 to Pr. 821, Pr. 830, 
Pr. 831, Pr. 880) 
 
 
(1) Block diagram of easy gain tuning function
The ratio of the load inertia to the motor inertia (load inertia moment) is estimated in real time from the torque
command and speed during motor operation by vector control. As optimum gain of speed control and position
control are automatically set from the load inertia ratio and response level, time and effort of making gain
adjustment are reduced. (Easy gain tuning)
When the load inertia ratio cannot be estimated due to load fluctuation or Real sensorless vector control is
exercised, control gain is automatically set by manually inputting the load inertia ratio.
Make a manual input adjustment when vibration, noise or any other unfavorable phenomenon occurs due to
large load inertia or gear backlash, for example, or when you want to exhibit the best performance that matches
the machine.
Parameter 
Number
Name
Initial Value
Setting Range
Description
818
Easy gain tuning 
response level setting
2
1 to 15
Set the response level.
1: Slow response to 15: Fast response
819
Easy gain tuning 
selection
0
0
Without easy gain tuning
1
With load estimation, with gain calculation
(valid only during vector control)
2
With load (Pr. 880) manual input, gain calculation
820
Speed control P gain 1
60%
0 to 1000%
Set the proportional gain for speed control. 
(Increasing the value improves trackability in 
response to a speed command change and 
reduces speed variation with disturbance.)
821
Speed control integral 
time 1
0.333s
0 to 20s
Set the integral time during speed control. 
(Decrease the value to shorten the time taken for 
returning to the original speed if speed variation 
with disturbance occurs.)
830
Speed control P gain 2
9999
0 to 1000%
Second function of Pr. 820 (valid when RT signal is 
on)
9999
No function
831
Speed control integral 
time 2
9999
0 to 20s
Second function of Pr. 821 (valid when RT signal is 
on)
9999
No function
880
Load inertia ratio
7 times
0 to 200 times
Set the load inertia ratio to the motor.
Sensorless
Sensorless
Sensorless
Vector
Vector
Vector
<Vector control>
Automatic setting
Speed control/position loop gain
Model speed control gain
[Pr. 820, Pr. 821, Pr. 828, Pr. 422]
Command
+
+
-
-
ON when [Pr. 819 = "1, 2"]
Gain table
Load inertia ratio
[Pr. 880]
Response level 
setting [Pr. 818]
ON when 
[Pr. 819 = "1"]
Current 
control
Load inertia 
ratio estimation 
section
Speed/position feedback
Actual motor speed
Motor
Detector
Encoder
Load 
inertia 
moment
Torque command