111
4
4
Motor speed is 
unstable.
(1) The speed command varies.
(1) -1 Check that a correct speed command comes from the 
command device. (Take measures against noises.)
(1) -2 Decrease Pr. 72 PWM frequency selection.
(1) -3 Increase Pr. 822 Speed setting filter 1(Refer to page 292)
(2) Insufficient torque.
(2) Increase the torque limit value.
(Refer to torque limit of speed control on page 100)
(3) The speed control gains do not 
match the machine. (mechanical 
resonance)
(3) -1 Perform easy gain tuning. (Refer to page 106)
(3) -2 Adjust Pr. 820, Pr. 821(Refer to page 108)
(3) -3 Perform speed feed forward/model adaptive speed 
control.
5
Motor or machine 
hunts (vibration/
noise is produced).
(1) The speed control gain is high.
(1) -1 Perform easy gain tuning. (Refer to page 106)
(1) -2 Decrease Pr. 820 and increase Pr. 821.
(1) -3 Perform speed feed forward control and model adaptive 
speed control.
(2) The torque control gain is high.
(2) Decrease the Pr. 824 value. (Refer to page 130)
(3) The motor wiring is wrong.
(3) Check the wiring
6
Acceleration/
deceleration time 
does not match the 
setting.
(1) Insufficient torque.
(1) -1 Increase the torque limit value.
(Refer to torque limit of speed control on page 100)
(1) -2 Perform speed feed forward control.
(2) Large load inertia.
(2) Set the acceleration/deceleration time that meets the load.
7
Machine operation is 
unstable
(1) The speed control gains do not 
match the machine.
(1) -1 Perform easy gain tuning. (Refer to page 106)
(1) -2 Adjust Pr. 820, Pr. 821(Refer to page 108)
(1) -3 Perform speed feed forward control and model adaptive 
speed control.
(2) Slow response because of 
improper acceleration/
deceleration time of the inverter.
(2) Change the acceleration/deceleration time to an optimum 
value.
8
Speed fluctuates at 
low speed.
(1) Adverse effect of high carrier 
frequency.
(1) Decrease Pr. 72 PWM frequency selection.
(2) Low speed control gain.
(2) Increase Pr. 820 Speed control P gain 1.
Phenomenon
Cause
Countermeasures