Справочник Пользователя для Mitsubishi Electronics FR-A700

Скачать
Страница из 523
Adjustment of Real sensorless vector 
control, vector control
144
4.7 Adjustment of Real sensorless vector control, vector 
control
4.7.1
Speed detection filter and torque detection filter (Pr. 823, Pr. 827, Pr. 833, Pr. 
837) 
 
(1) Stabilize speed detection (Pr. 823, Pr. 833 )
⋅ Since the current loop response reduces, use it with the initial value.
Increase the setting value gradually and adjust the value to stabilize the speed when speed ripples occur due to
harmonic disturbance, etc. A too large value will run the motor unstably.
⋅ Pr. 823 and Pr. 833 are valid only during vector control
(2) Stabilize speed detection (Pr. 827, Pr. 837 )
⋅ Since the current loop response reduces, use it with the initial value.
Increase the setting value gradually and adjust the value to stabilize the speed when torque ripples occur due to
harmonic disturbance, etc. A too large value will run the motor unstably.
(3) Use multiple primary delay filters.
⋅ Use Pr. 833 and Pr. 837 to change the filter according to applications.  Pr. 833 and Pr. 837 are valid when the RT
signal is ON.
Purpose
Parameter that should be Set
Refer to Page
Stabilize speed and feedback signal
Speed detection filter
Torque detection filter
Pr. 823, Pr. 827, Pr. 833, Pr. 837
Change the excitation ratio
Excitation ratio
Pr. 854
Set the time constant of the primary delay filter relative to the speed feedback signal and torque feedback signal.
Since this function reduces the speed loop response, use it with the initial value.
Parameter 
Number
Name
Initial Value
Setting Range
Description
823
 *1
Speed detection filter 1
0.001s
0
Without filter
0.001 to 0.1s
Set the time constant of the primary delay filter 
relative to the speed feedback signal.
827
Torque detection filter 1
0s
0
Without filter
0.001 to 0.1s
Set the time constant of the primary delay filter 
relative to the torque feedback signal.
833 
*1
Speed detection filter 2
9999
0 to 0.1s
Second function of Pr. 823 (valid when RT signal is 
on)
9999
Same as the  Pr. 823 setting
837
Torque detection filter 2
9999
0 to 0.1s
Second function of Pr. 827 (valid when RT signal is 
on)
9999
Same as the  Pr. 827 setting
*1
This parameter can be set when the FR-A7AP/FR-A7AL (option) is mounted.
REMARKS
⋅ The RT signal acts as the second function selection signal and makes the other second functions valid. (Refer to page 235.)
⋅ The RT signal is assigned to the RT terminal in the initial setting. By setting "3" in any of Pr. 178 to Pr. 189 (input terminal function
selection) , you can assign the RT signal to the other  terminal.
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Sensorless
Vector
Vector
Vector