Справочник Пользователя для Mitsubishi Electronics FR-A700

Скачать
Страница из 523
220
Motor brake and stop operation
4.14.6 Orientation control (Pr. 350 to Pr. 366, Pr. 369, Pr. 393, Pr. 396 to Pr. 399)
 
 
 
This function is used with a position detector (encoder) installed to the spindle of a machine tool, etc. to allow a
rotation shaft to be stopped at the specified position (oriented).
Option FR-A7AP/FR-A7AL is necessary.
Pr. 350 Stop position command selection is initially set to "9999", orientation control function is invalid.
Parameter 
Number
Name
Initial 
Value
Setting 
Range
Description
350
Stop position command 
selection
9999
0
Internal stop position command (Pr. 356)
1
External stop position command (FR-A7AX 16-bit digital 
input)
9999
Orientation control invalid
351
Orientation speed
2Hz
0 to 30Hz
Decrease the motor speed to the set value when the 
orientation command (X22) is given.
352
Creep speed
0.5Hz
0 to 10Hz
After the speed reaches the orientation speed, the speed 
decreases to the creep speed set in Pr. 352 as soon as the 
current position pulse reaches the creep switchover 
position set in Pr. 353.
353
Creep switchover 
position
511
0 to 16383*
354
Position loop switchover 
position
96
0 to 8191
As soon as the current position pulse reaches the set 
position loop switchover position, control is changed to 
position loop.
355
DC injection brake start 
position
5
0 to 255
After changed to position loop, DC injection brake is 
applied and the motor stops as soon as the current 
position pulse reaches the set DC injection brake start 
position.
356
Internal stop position 
command
0
0 to 16383*
When "0" is set in Pr. 350, the internal position command is 
activated and the setting value of Pr. 356 becomes a stop 
position.
357
Orientation in-position 
zone
5
0 to 255
Set the in-position zone at a stop of the orientation.
358
Servo torque selection
1
0 to 13
Functions at orientation complete can be selected.
359
Encoder rotation 
direction
1
0
Set the rotation 
direction according 
to the motor 
specification.
1
360
16-bit data selection
0
0
Speed command
When 1 is set in Pr. 
350
 and the FR-
A7AX is mounted, 
set a stop position 
using 16-bit data.
Stop position 
command is input as 
binary regardless of 
the Pr. 304 setting.
1
16 bit data is used as external 
position command as is.
2 to 127
Set the stop position dividing up to 
128 stop positions at regular 
intervals.
361
Position shift
0
0 to 16383*
Shift the origin using a compensation value without 
changing the origin of the encoder. The stop position is a 
position obtained by adding the setting value of Pr. 361 to 
the position command.
362
Orientation position loop 
gain
1
0.1 to 100
When servo torque function is selected using Pr. 358
output frequency for generating servo torque increases to 
the creep speed of Pr. 352 gradually according to the slope 
set in Pr. 362. Although the operation becomes faster 
when the value is increased, a machine may hunt, etc.
363
Completion signal output 
delay time
0.5s
0 to 5.0s
The orientation complete signal is output delaying the set 
time after in-position zone is entered.  Also, the signal 
turns OFF delaying the set time after in-position zone is 
out.
V/F
V/F
V/F
Magnetic flux
Magnetic flux
Magnetic flux
Vector
Vector
Vector
A
Encoder
CW
Clockwise direction as viewed 
from A is forward rotation
CCW
A
Encoder
Counter clockwise direction as 
viewed from A is forward rotation