Справочник Пользователя для Mitsubishi Electronics FR-A700

Скачать
Страница из 523
14/24
BCN-C22005-634
1.6
Low-speed range torque characteristics (Pr.788) 
ÅtÅ
s
I
P
M
Å
t
* Current synchronization operation is always performed for IPM motors other than MM-CF, even if "9999" is set.
(1) When the low-speed range torque characteristic is enabled ("9999" (initial value))
· The high frequency superposition control provides enough torque in the low-speed range operation.
· Refer to page 17 for the torque characteristics.
(2) When the low-speed range torque characteristic is disabled ("0")
· The current synchronization operation reduces much motor noise compared with the high frequency superposition
control.
· The torque in a low-speed range is low. Use this setting for an operation with light start-up load.
· Refer to page 17 for the torque characteristics.
1.7
Setting the acceleration/deceleration time in the low-speed range
 (Pr.791, Pr.792)
 
Torque characteristics in a low-speed range can be changed.
Parameter 
Number
Name
Initial 
Setting
Setting 
Range
Operation
788
Low-speed range torque 
characteristics
9999
0
Disables the low-speed range torque characteristic 
(current synchronization operation).
9999
*
Enables the low-speed range torque characteristic 
(high frequency superposition control)
REMARKS
 Position control under PM sensorless vector control is not available when the current synchronization operation is selected.
Parameter 
Number
Name
Initial 
Value
Setting Range
Description
791
Acceleration time in 
low-speed range
9999
0 to 3600/360s
*
Set the acceleration time in a low-speed 
range (less than 1/10 of the rated motor 
frequency).
9999
The acceleration time set in Pr.7 is applied. 
(When the second functions are enabled, 
the settings are applied.)
792
Deceleration time in 
low-speed range
9999
0 to 3600/360s
*
Set the deceleration time in a low-speed 
range (less than 1/10 of the rated motor 
frequency).
9999
The deceleration time set in Pr.8 is applied. 
(When the second functions are enabled, 
the settings are applied.)
* Depends on the Pr. 21 Acceleration/deceleration time increments setting. The initial value for the setting range is "0 to 3600s" and the setting
increments is "0.1s".
P M
P M
P M
P M
P M
P M
P M
P M
P M
P M
P M
P M
P M
P M
P M
bcnc22005634.fm  14 ページ  2012年7月3日 火曜日 午前9時43分