Справочник Пользователя для Mitsubishi Electronics FR-A700

Скачать
Страница из 523
15/24
BCN-C22005-634
If torque is required in a low-speed range (less than 1/10 of the rated motor frequency), set Pr.791 Acceleration time in
low-speed range
 and Pr.792 Deceleration time in low-speed range settings higher than the Pr.7 Acceleration time and Pr.8
Deceleration time
 settings so that the mild acceleration/deceleration is performed in the low-speed range. (For an
operation with second acceleration/deceleration times, set the acceleration/deceleration times longer than the second
acceleration/deceleration times.)
1.8
DC injection brake of the PM sensorless vector control 
DC injection brake under PM sensorless vector control is performed as below.
REMARKS
 Set Pr.791 higher than Pr.7, and Pr.792 higher than Pr.8. If set as Pr.791 < Pr.7, the operation is performed as Pr.791 = Pr.7. If
set as Pr.792 < Pr.8, the operation is performed as Pr.792 = Pr.8.
 Refer to page 6 for the rated motor frequency of MM-CF.
REMARKS
 The X13 signal is disabled during PM sensorless vector control.
Low-speed range 
(rated motor frequency/10)
Acceleration time  
Slope set by Pr.7
Deceleration time 
Slope set by Pr.8
Deceleration time 
in low-speed range
Slope set by Pr.792
Acceleration time 
in low-speed range 
Slope set by Pr. 791
Time
Output 
frequency 
(Hz)
P M
P M
P M
 
 
Time
Time
Time
Pr.11
Calculated speed
Calculated speed
<High frequency superposition control (Pr.788 = "9999 (initial value)")>
Commanded speed
Commanded speed
 
Pr.10
Pr.10
Output frequency
(Hz)
Output frequency
(Hz)
DC braking voltage
(V)
When Pr.11 = "0"
When Pr.11     "0"
DC injection brake applied 
when:
The commanded speed =  0Hz
The calculated speed      Pr.10
Motor coasting when:
The commanded speed     Pr.10
The calculated speed     Pr.10
Motor coasting when:
The commanded speed     Pr.10
The calculated speed     Pr.10
 
Pr.11
Time
Pr.10
 
 
Time
Time
<Current synchronization operation Pr.788 = "0">
When Pr.11 = "0"
When Pr.11     "0"
Calculated speed
Commanded 
speed
DC injection brake applied when 
the commanded and calculated 
speeds are 0Hz
Output frequency
(Hz)
Output frequency
(Hz)
DC braking voltage
(V)
bcnc22005634.fm  15 ページ  2012年7月3日 火曜日 午前9時43分