Справочник Пользователя для Mitsubishi Electronics FR-D720S-0.1K to 2.2K

Скачать
Страница из 52
11
2.3.3
Terminal arrangement of the main circuit terminal, power supply and the motor wiring
z
Three-phase 200V/400V class
z
Single-phase 200V class
z
Single-phase 100V class
FR-D720-0.1K to 0.75K
FR-D720-1.5K to 3.7K
FR-D740-0.4K to 3.7K
FR-D720-5.5K, 7.5K
FR-D740-5.5K, 7.5K
FR-D720-11K, 15K
FR-D740-11K, 15K
FR-D720S-0.1K to 0.75K
FR-D720S-1.5K, 2.2K
FR-D710W-0.1K to 0.4K
FR-D710W-0.75K
NOTE
y
Make sure the power cables are connected to the R/L1, S/L2, T/L3. (Phase need not be matched.) Never connect the
power cable to the U, V, W of the inverter. Doing so will damage the inverter.
y
Connect the motor to U, V, W. Turning ON the forward rotation switch (signal) at this time rotates the motor
counterclockwise when viewed from the load shaft.
Motor
Power supply
N/-
P/+
PR
IM
R/L1 S/L2 T/L3
Jumper
Motor
Power supply
N/-
P/+
PR
IM
R/L1 S/L2 T/L3
Jumper
Power supply Motor
IM
Jumper
N/-
P/+ PR R/L1 S/L2 T/L3
N/-
P/+
PR
R/L1
S/L2
T/L3
Jumper
Motor
Power supply
IM
Motor
Power supply
IM
N/-
P/+ PR R/L1 S/L2 T/L3
Jumper
Motor
Power supply
N/-
P/+
PR
IM
Jumper
R/L1 S/L2
N/-
P/+
PR
R/L1 S/L2
Motor
Power supply
IM
Jumper
Motor
Power supply
N/-
P/+
PR
IM
R/L1 S/L2
N/-
P/+
PR
R/L1 S/L2
Motor
Power supply
IM