Справочник Пользователя для Mitsubishi Electronics FR-D720S-0.1K to 2.2K

Скачать
Страница из 52
9
2.3.2
Terminal specifications
Type
Terminal
Symbol
Terminal Name
Terminal Specification
M
ai
n
 c
irc
u
it 
ter
m
inal
R/L1, S/L2, 
T/L3
 
AC power input
Connect to the commercial power supply. 
Do not connect anything to these terminals when using the high power factor converter (FR-
HC) or power regeneration common converter (FR-CV).
* When using single-phase power input, terminals are R/L1 and S/L2.
U, V, W
Inverter output
Connect a three-phase squirrel-cage motor.
P/+, PR
Brake resistor connection
Connect a brake resistor (FR-ABR, MRS type, MYS type) across terminals P/+ and PR.
(The brake resistor can not be connected to the 0.1K and 0.2K.)
P/+, N/-
Brake unit connection
Connect the brake unit (FR-BU2), power regeneration common converter (FR-CV) or high 
power factor converter (FR-HC).
P/+, P1
 
DC reactor connection
Remove the jumper across terminals P/+ and P1 and connect a DC reactor. (Single-phase 
100V power input model is not compatible with the DC reactor.)
* Terminal P1 is not available for single-phase 100V power input model.
Earth (Ground)
For earthing (grounding) the inverter chassis. Must be earthed (grounded).
Con
tr
ol
 c
ir
cu
it te
rm
in
al
/Inpu
t s
ig
nal
Con
tac
t i
npu
t
STF
Forward rotation start
Turn ON the STF signal to start forward rotation and turn it OFF 
to stop.
When the STF and STR 
signals are turned ON 
simultaneously, the stop 
command is given.
STR
Reverse rotation start
Turn ON the STR signal to start reverse rotation and turn it 
OFF to stop.
RH, RM, RL
Multi-speed selection
Multi-speed can be selected according to the combination of RH, RM and RL signals.
SD
Contact input common 
(sink) (initial setting)
Common terminal for contact input terminal (sink logic) and terminal FM.
External transistor 
common (source)
Connect this terminal to the power supply common terminal of a transistor output (open 
collector output) device, such as a programmable controller, in the source logic to avoid 
malfunction by undesirable current.
24VDC power supply 
common
Common output terminal for 24VDC 0.1A power supply (PC terminal).
Isolated from terminals 5 and SE.
PC
External transistor 
common (sink) 
(initial setting)
Connect this terminal to the power supply common terminal of a transistor output (open 
collector output) device, such as a programmable controller, in the sink logic to avoid 
malfunction by undesirable current.
Contact input common 
(source)
Common terminal for contact input terminal (source logic).
24VDC power supply
Can be used as 24VDC 0.1A power supply.
F
requ
enc
y s
e
tti
n
g
10
Frequency setting power 
supply
Used as power supply when connecting potentiometer for 
frequency setting (speed setting) from outside of the inverter.
5VDC
permissible load current 
10mA
2
Frequency setting 
(voltage)
Inputting 0 to 5VDC (or 0 to 10V) provides the maximum output 
frequency at 5V (10V) and makes input and output 
proportional. Use Pr. 73 to switch between input 0 to 5VDC 
input (initial setting) and 0 to 10VDC.
Input resistance10k
Ω ± 1kΩ
Permissible maximum voltage 
20VDC
4
Frequency setting 
(current)
Inputting 4 to 20mADC (or 0 to 5V, 0 to 10V) provides the 
maximum output frequency at 20mA and makes input and 
output proportional. This input signal is valid only when the AU 
signal is ON (terminal 2 input is invalid). To use terminal 4 
(initial setting is current input), set "4" in any of Pr.178 to Pr.182 
(input terminal function selection)
 to assign the function, and turn 
ON AU signal.
Use Pr. 267 to switch among input 4 to 20mA (initial setting), 0 
to 5VDC and 0 to 10VDC. Set the voltage/current input switch 
in the "V" position to select voltage input (0 to 5V/0 to 10V).
Current input:
Input resistance 249
Ω ± 5Ω
Maximum permissible current 
30mA
Voltage input:
Input resistance10k
Ω ± 1kΩ
Permissible maximum voltage 
20VDC
5
Frequency setting 
common
Frequency setting signal (terminal 2, 4) common terminal. Do not earth (ground).
T
her
m
is
tor
10
2
PTC thermistor input
For connecting PTC thermistor output.
When PTC thermistor protection is valid (Pr. 561 
≠ "9999"), 
terminal 2 is not available for frequency setting.
Adaptive PTC thermistor 
specification
Heat detection resistance : 
500
Ω to 30kΩ (Set by Pr. 561)