1.2 Operation panel
1.2.1
Names and functions of the operation panel
The operation panel cannot be removed from the inverter.
Operation mode indicator
PU:  Lit to indicate PU operation mode.
EXT:  Lit to indicate External operation mode.
(Lit at power-ON at initial setting.)
NET:  Lit to indicate Network operation mode.
PU, EXT: Lit to indicate External/PU 
combined operation mode 1, 2.
These turn OFF when command source is 
not on operation panel.
Unit indicator
Hz: Lit to indicate frequency.
(Flickers when the set frequency 
monitor is displayed.)
A: Lit to indicate current.
(Both "Hz" and "A" turn OFF when other 
than the above is displayed.)
Monitor (4-digit LED)
Shows the frequency, parameter number, 
etc.
Setting dial
(Setting dial: Mitsubishi inverter dial)
The setting dial is used to change the 
frequency and parameter settings.
Press the setting dial to perform the 
following operations:
y
 To display a set frequency in the 
monitor mode 
y
 To display the present setting during 
calibration 
y
 To display a fault history number in the 
faults history mode
Mode switchover
Used to switch among different setting 
modes.
Pressing  
simultaneously 
changes 
the operation mode.
Pressing for a while (2s) can lock 
operation. (
 
Refer to the Instruction 
Manual (Applied))
Determination of each setting
If pressed during operation, monitor 
changes as below:
Running frequency
Output current
Output voltage
Operating status indicator
Lit or flicker during inverter operation.  ∗
* Lit: When the forward rotation operation
is being performed.
Slow flickering (1.4s cycle): 
When the reverse rotation operation
is being performed.
Fast flickering (0.2s cycle):
y
When 
 was pressed or the start 
command was given, but the 
operation cannot be made.
y
When the frequency command is less 
than the starting frequency.
y
When the MRS signal is input.
Parameter setting mode indicator
Lit to indicate parameter setting mode.
Monitor indicator
Lit to indicate monitoring mode.
STOP operation
Used to stop operation commands.
Used to reset a fault when the protective 
function (fault) is activated.
Operation mode switchover
Used to switch between the PU and 
External operation modes.
To use the External operation mode 
(operation using a separately connected 
frequency setting potentiometer and start 
signal), press this key to light up the EXT 
indicator.
(Press 
 simultaneously (0.5s), or 
change Pr. 79 setting to change to combined 
mode .) (
 
Refer to the Instruction 
Manual (Applied))
PU: PU operation mode
EXT: External operation mode
Cancels PU stop also.
Start command
The rotation direction can be selected by 
setting Pr. 40.