the electrical requirement on the nameplate. Please 
make sure that your unit has its own dedicated 
outlet. Do not use an extension cord. 
The temperature controls are preset at the factory 
to maintain an average temperature of 38 F in 
refrigerators. To maintain a different temperature, 
simply adjust the control knob located inside the 
unit. Temperature ranges from 7 (coldest) to 1 
(warmest). Setting the temperature control to the 
coldest setting may cause the evaporator coil to 
freeze and ice up. This will eventually make the 
cabinet become warm, which is not recommended. 
 
 
Appliance Start‐up 
 
Once the appliance has been located in its 
permanent location and the proper power and 
grounding has been provided, the following items 
must be checked or completed: 
 
Cool Down Period 
For safe food storage, allow 24 hours for the 
appliance to cool down completely before loading 
with food. The appliance will run continuously for 
the first several hours. Do not place any food in the 
appliance until after the first 24 hours of operation. 
 
Thermostat Setting
 
The appliance is shipped from the factory with the 
thermostat set at about the midpoint of the 
operating range. Adjustments colder or warmer can 
be made after the appliance has been running for at 
least 8 hours. Allow at least 8 hours for temperature 
stabilization before readjusting the thermostat. 
 
Defrost Setting 
The appliance is designed to defrost automatically 
every 12 hours. To set the time of defrost, wait until 
the desired time to defrost. With the notch on the 
timer knob aligned with the line on the bracket (Fig. 
A), turn the defrost timer knob clockwise slowly. 
The timer will click several times, then once loudly, 
at which point the defrost cycle begins. The timer 
knob will advance through the defrost cycle, then 
click loudly at the end of the cycle (Fig. B). The 
appliance will defrost automatically every 12 hours 
after the first defrost cycle. 
 
 
Routine Maintenance 
 
Cleaning the Interior 
Be sure to turn the temperature control to “OFF” 
and unplug the electrical cord. Wash the inside 
surface of the storage area with warm water and 
baking soda solution (about one tablespoon of 
baking soda per quart of warm water). Rinse 
thoroughly with clean, warm water and wipe dry. 
 
Cleaning the Exterior 
Wipe the cabinet exterior occasionally with a cloth 
dampened in mild detergent and water. Rinse and 
wipe dry with a soft cloth. Do not use razor blades 
or other sharp instruments that can scratch the 
appliance surface when removing adhesive labels. 
Any glue left from the tape can be removed with a 
mixture of warm water and mild detergent or touch 
the residue with the sticky side of tape already 
removed. DO NOT REMOVE THE SERIAL PLATE
 
Condensate Pan 
Some models have a condensate pan in a fixed 
position located behind the toe grill. This must not 
be removed from under the cabinet. If the pan is 
removed, condensate will drop onto the floor. 
 
POWER FAILURE 
DO NOT open the appliance lid unnecessarily if the 
appliance is off for several hours. 
If a power failure  
occurs, pack seven or eight pounds of dry ice into 
the appliance every 24 hours. Look in the Yellow 
Pages under “Dry Ice”, “Dairies”, or “Ice Cream 
Manufacturers” for local dry ice suppliers. Always 
wear gloves and use caution when handling dry ice. 
 
Operation 
 
™  Run the unit for at least 24 hours before 
loading. 
™  When loading the unit: 
•  Be careful not to block the air duct located 
at the back and the fan on the ceiling of the 
unit with contents. 
•  Blocking the air flow may cause decrease in 
performance.