Temperature Controller Manual 
 
Feature of Function  
This temperature controller adopt world well‐
known brand SCM. It is reliable and durable. The 
relay is exclusively used for compressor loads which 
make it safer. The way of controlling temperature is 
return type and easy to operate. 
Mine‐sized and integrated intelligent control, it is 
applicable to the compressor of one H.P. Suit for a 
ventilated freezer. 
Main functions 
•  Temperature display (Celsius/Fahrenheit 
degrees) 
•  Temperature control 
•  Evaporator fan control (parallel with 
compressor or continuous running changes) 
•  Manual, automatic defrost by electric heater 
•  Time or temperature setting to end defrost 
•  The cold‐room sensor temperature can lock 
during defrost 
•  Parameter locking  
•  The factor default resumption  
•  Offset on sensor temperature  
•  Self testing 
Specification  
•  Power supple: 12V ~, 50/60Hz; Power 
consumption: < 5W 
•  Range of temperature displayed:‐  5 45 C      
(‐40~120 F)  
4 ~
•  R
temperature: ‐45~45 C  
ange of set 
(‐40~120 F) 
•  Temperature sensor: NTC, double sensor. 
•  Output contact capacity for compressor: N.O. 
20A/250V~; 50/60Hz. The inrush current for 
compressor control may be 20A instead of 8A 
during the period of 1s at start. (applicable to 1 
H.P. compressor if more connected to AC 
contactor) 
•  Output contact capacity for Evap. Fan: N.O. 
20a/250V~; 50/60Hz. 
•  Main controller panel dimension 78
X
35
X
76mm. 
Mounting dimension: 71:29mm 
Indicator 
•  Refrigerant: When the refrigerant LED is on, the 
compressor is working. 
•  Constant temperature: When the refrigerant 
LED is off, the compressor has stopped. 
•  Delay: When the refrigerant LED flashes, the 
compressor stops. 
•  Defrost: When the defrost LED is on, the 
compressor and fan stop and the heater works. 
•  Evaporator fan: When the fan LED is on, the fan 
is working. 
Front Panel Operation  
•  Set temperature: Press  button, the set 
temperature is displayed; Press or button to 
modify and store the displayed value, press 
 
button to exit the adjustment and display the 
cold‐room temperature. 
•  Manual start/stop defrost: Press   button and 
hold for 6 seconds to defrost or stop defrost.  
•  Display the evaporator temperature: Press   
button and hold for 6 seconds. The evaporator 
temperature will be displayed. After 10 
seconds, the cold‐room temperature is resumed 
to be displayed. 
Parameter Setup 
•  Indication for setting parameter: The parameter 
can be adjusted only after correct PA has been 
entered. All parameters can only be checked,