Model number nomenclature
a30-4744
30XW –  325 6 – 
– 
– 
– 
3  B
30XW – AquaForce
®
 Water-Cooled 
     
Screw Chiller
Design Series
Unit Size (Nominal Tons) (kW)
325
  –  325 (1133)
350  –  350 (1206)
400  –  400 (1354)
Voltage
1
  –  575-3-60
2  –  380-3-60
4  –  230-3-60
6  –  460-3-60
7  –  200-3-60
Condenser Options
-
   –  2 Pass, NIH, 150 psig (1034 kPa), Victaulic, Discharge Connections (Std)
0  –  2 Pass, NIH, 150 psig (1034 kPa), Victaulic, Suction Connections
1  –  2 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Connections
2  –  2 Pass, NIH, 150 psig (1034 kPa), Flange, Suction Connections
3  –  2 Pass, NIH, 300 psig (2068 kPa), Victaulic, Discharge Connections
4  –  2 Pass, NIH, 300 psig (2068 kPa), Victaulic, Suction Connections
 –  2 Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Connections
6  –  2 Pass, NIH, 300 psig (2068 kPa), Flange, Suction Connections
7  –  2 Pass, MWB, 150 psig (1034 kPa), Victaulic, Discharge Connections
8  –  2 Pass, MWB, 150 psig (1034 kPa), Victaulic, Suction Connections
9  –  2 Pass, MWB, 300 psig (2068 kPa), Victaulic, Discharge Connections
B  –  2 Pass, MWB, 300 psig (2068 kPa), Victaulic, Suction Connections
C  –  2 Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Connections
D  –  2 Pass, MWB, 150 psig (1034 kPa), Flange, Suction Connections
F  –  2 Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Connections
G –  2 Pass, MWB, 300 psig (2068 kPa), Flange, Suction Connections
H  –  1 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Leaving
J  –  1 Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Leaving
K  –  1 Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Leaving
L  –  1 Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Leaving
Heat Machine
-
   –  Std Condenser/Comfort Cooling (Std)
M –  Heat Machine Condenser/Comfort Cooling
Evaporator Options
-
    – 2 Pass, NIH, 150 psig (1034 kPa), Victaulic, Discharge Connections (Std)
 –  2 Pass, NIH, 150 psig (1034 kPa), Victaulic, Suction Connections
 –  2 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Connections
 –  2 Pass, NIH, 150 psig (1034 kPa), Flange, Suction Connections
 –  2 Pass, NIH, 300 psig (2068 kPa), Victaulic, Discharge Connections
 –  2 Pass, NIH, 300 psig (2068 kPa), Victaulic, Suction Connections
 –  2 Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Connections
 –  2 Pass, NIH, 300 psig (2068 kPa), Flange, Suction Connections
 –  2 Pass, MWB, 150 psig (1034 kPa), Victaulic, Discharge Connections
 –  2 Pass, MWB, 150 psig (1034 kPa), Victaulic, Suction Connections
 –  2 Pass, MWB, 300 psig (2068 kPa), Victaulic, Discharge Connections
 –  2  Pass, MWB, 300 psig (2068 kPa), Victaulic, Suction Connections
 –  2  Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Connections
 –  2  Pass, MWB, 150 psig (1034 kPa), Flange, Suction Connections
 –  2  Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Connections
– 2 Pass, MWB, 300 psig (2068 kPa), Flange, Suction Connections
– 1 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Leaving
– 1 Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Leaving
 –  1  Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Leaving
 –  1  Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Leaving
–  3 Pass, NIH, 150 psig (1034 kPa), Flange, Discharge Leaving
 –  3 Pass, NIH, 150 psig (1034 kPa), Flange, Suction Leaving
 –  3 Pass, NIH, 300 psig (2068 kPa), Flange, Discharge Leaving
–  3 Pass, NIH, 300 psig (2068 kPa), Flange, Suction Leaving
 –  3 Pass, MWB, 150 psig (1034 kPa), Flange, Discharge Leaving
 –  3 Pass, MWB, 150 psig (1034 kPa), Flange, Suction Leaving
 –  3 Pass, MWB, 300 psig (2068 kPa), Flange, Discharge Leaving
 –  3 Pass, MWB, 300 psig (2068 kPa), Flange, Suction Leaving
Packaging/Charging Options
 –  R-134a Refrigerant with Bag (Std)
 –  R-134a Refrigerant with Crate Over Bag 
 –  Nitrogen  Refrigerant with Bag
 –  Nitrogen  Refrigerant with Crate Over Bag
Controls/Communications Options
-   –  Navigator™ Display
 –  Navigator Display, EMM
 –  Navigator Display, GFCI Service Option
 –  Navigator Display, EMM, GFCI Service Option
 –  Touch Pilot™ Display (Std)
 –  Touch Pilot, EMM
 –  Touch Pilot, GFCI Service Option
 –  Touch Pilot, EMM, GFCI Service Option
 –  Navigator Display, BACnet™ Translator
 –  Navigator Display, EMM, BACnet Translator
 –  Navigator Display, GFCI Service Option, 
 BACnet 
Translator
 –  Navigator Display, EMM, GFCI Service Option, 
 BACnet 
Translator
 –  Touch Pilot Display (Std), BACnet Translator
 –  Touch Pilot Display, EMM, BACnet Translator
 –  Touch Pilot Display, GFCI Service Option, 
 BACnet 
Translator
– Touch Pilot Display, EMM, GFCI Service Option, 
 BACnet 
Translator
 –  Navigator Display, LON Translator
 –  Navigator Display, EMM, LON Translator
 –  Navigator Display, GFCI Service Option, 
 LON 
Translator
 –  Navigator Display, EMM, GFCI Service Option, 
 LON 
Translator
M –  Touch Pilot Display (Std), LON Translator
 –  Touch Pilot Display, EMM, LON Translator
 –  Touch Pilot Display, GFCI Service Option, 
 LON 
Translator
– Touch Pilot Display, EMM, GFCI Service 
 Option, 
LON 
Translator
Electrical Options
 –  Single Point, XL Starter, Terminal Block 
  (Std 380, 460, 575-v)
 –  Single Point, Wye-Delta Starter, Terminal 
 Block 
(Std 200,230-v)
 –  Dual Point, XL Starter, Terminal Block
 –  Dual Point, Wye-Delta Starter, Terminal Block
 –  Single Point, XL Starter, Non-Fused Disconnect
 –  Single Point, Wye-Delta, Non-Fused Disconnect
 –  Dual Point, XL Starter, Non-Fused Disconnect
 –  Dual Point, Wye-Delta Starter, Non-Fused 
 Disconnect
 –  Single Point, XL Starter, Terminal Block, CPT
 –  Single Point, Wye-Delta Starter, Terminal 
 Block, 
CPT
– Dual Point, XL Starter, Terminal Block, CPT
 –  Dual Point, Wye-Delta Starter, Terminal 
 Block, 
CPT
 –  Single Point, XL Starter, Non-Fused 
 Disconnect, CPT
 –  Single Point, Wye-Delta, Non-Fused 
 Disconnect, CPT
– Dual Point, XL Starter, Non-Fused 
 Disconnect, CPT
 –  Dual Point, Wye-Delta Starter, Non-Fused 
 Disconnect, CPT
Refrigeration Circuit Options
*
 –  Standard Unit 
 –  With Suction Service Valves
 –  With  Minimum Load Control 
– With Suction Service Valves and Minimum 
 Load Control 
 –  With  Condenser Insulation for Heat Machine 
– With Suction Service Valves and Condenser 
 Insulation for Heat Machine 
 –  With  Minimum Load Control and Condenser 
 Insulation for Heat Machine 
 –  With  Suction Service Valves, Minimum Load 
 Control 
and Condenser Insulation for 
 Heat Machine 
LEGEND
*Evaporator insulation is standard.
Quality Assurance
Certified to ISO 9001:2000
CPT
— Control Power Transformer
MWB — Marine Waterbox
EMM
— Energy Management Module
NIH
— Nozzle-In-Head
GFCI
— Ground Fault Circuit Interrupter
XL
— Across-the-Line Start
LON
— Local Operating Network