B. Sequence of Operation
1. Sequence Cycles and Shutdown
The steps in the sequence are as outlined below. When power is supplied, the red 
"POWER OK" LED and the green "BC CLOSED" LED on the CB turn on (If yellow 
"BC OPEN" LED is on, the icemaker will not start. In this case clear ice away from BC 
actuator paddle in the storage bin area). A 5-second delay occurs at startup. Note that 
the order of the green sequence LEDs from the outer edge of the board is 1, 4, 3, 2.
a) 1-Minute Fill Cycle
LED 4 is on. WV1 opens and the fill period begins. After 1-minute, CB checks for closed 
F/S. If F/S is closed, the harvest cycle begins. If not, WV1 will remain energized through 
additional 1-minute cycles until water enters the water tank and F/S closes. This serves 
as a low water safety to protect the water pump.
b) Initial Harvest Cycle 
LEDs 1, 4 and 2 are on. Comp, FMRs, HGVs, X10 relay, WV2, X12 relay, and X13 
relay energize. WV1 de-energizes. CB monitors the warming of the evaporator via the 
thermistor located on the suction line. When the thermistor reaches 48°F (9°C), CB 
reads 3.9 kΩ from the thermistor and turns harvest termination over to the adjustable 
harvest timer (S4 dip switch 1 & 2). The harvest timer has settings of 60, 90, 120, and 
180 seconds. The pump-out timer (S4 dip switch 3 & 4) acts in place of the harvest timer 
during cycles with a pump-out (S4 dip switch 5 & 6). WV2 and X12 relay are energized 
during harvest for a maximum of 6 minutes or the length of harvest minus 50 seconds, 
whichever is shorter. 50 seconds before the harvest timer terminates, harvest pump timer 
starts. LED 4 turns off, WV2 and X12 relay de-energize. 
Harvest Pump Timer: LEDs 1, 3, and 2 are on. Comp, FMRs, HGVs, X10 relay, and 
X13 relay continue. LED 4 turns off, WV2 and X12 relay de-energize. LED 3 turns on and 
X11 relay energizes, allowing PM to energize for the last 50 seconds of harvest. 
NOTICE! 
S4 dip switch 7 must remain in the factory default position of 7 on. Otherwise, 
PM will not energize during the last 50 seconds of harvest. 
The minimum total 
time allowed by CB for a complete harvest cycle is 2 minutes. At the end of harvest, 
CB checks position of F/S and proceeds to the freeze cycle if it is closed or calls for a 
1-minute fill if it is open. 
c) Freeze Cycle 
LED 1 and LED 4 are on. Comp, FMRs, and PM remain energized. LLVs energize. WV1 
and LED 4 energize for 1 min. HGVs, X10, X11, and X13 relays de-energize. For the first 
5 minutes, CB will not terminate the freeze cycle. At the end of 5 minutes, F/S assumes 
control of the freeze cycle. As ice builds on the evaporator, the water level in the water 
tank lowers. Freeze continues until F/S opens, provided the 5-minute minimum freeze 
timer has terminated.