e) Harvest Pump Timer (S4 dip switch 7)
NOTICE
Factory set for proper operation. Do not adjust. Adjustment outside of the factory 
default setting may result in damage to the icemaker.
Depending on the harvest pump timer setting, the pump motor either stays off or is 
energized the last 50 seconds of harvest. When the pump motor is energized, water 
circulates over the evaporator. The harvest water valve is open during harvest for a 
maximum of 6 minutes or the length of harvest minus 0 or 50 seconds (determined by 
the harvest pump timer setting), whichever is shorter. 
When S4 dip switch 7 is in the on position and harvest begins, X10 relay energizes 
and allows the harvest water valve, X12, and X13 relays to energize. A lockout circuit is 
created using the X10, X12, and X13 relays. This prevents the drain valve from energizing 
during harvest pump timer. See "III.B. Wiring Diagram." 
50 seconds before harvest termination, LED 4 goes off de-energizing WV2 (harvest 
water valve) and X12 relay. X13 relay remains energized through the holding circuit 
through X10 and X13 relays. Next, LED 3 on the control board turns on and X11 relay 
energizes, allowing the pump motor to energize. The pump motor is energized the last 
50 seconds of harvest.
S4 Dip Switch Setting
Pump Motor 
Time (seconds)
No. 7
ON
50
OFF
0
f) Factory Use (S4 dip switch 8)
Factory set for proper operation. Do not adjust. This must be left in the factory default 
position.
g) Freeze Timer (S4 dip switch 9 & 10)
NOTICE
Adjust to proper specification, or the icemaker may not operate correctly.
The freeze timer setting determines the maximum allowed freeze time to prevent possible 
freeze-up issues. Upon termination of freeze timer, the control board initiates the harvest 
cycle. After 2 consecutive freeze timer terminations, the control board shuts down the 
icemaker. In this case, see "IV.F.3. Low Ice Production" for possible solutions.
The freeze timer is factory set, and generally no adjustment is required. Before changing
this setting, contact your local Hoshizaki distributor or Hoshizaki Technical Support for
recommendations.
Dip Switch Setting
Time 
(minutes)
No. 9
No. 10
OFF
OFF
60
OFF
ON
50
ON
OFF
70
ON
ON
60