3. Controls and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely 
affect performance and warranty coverage. For more information, contact Hoshizaki 
Technical Support at 1-800-233-1940.
a) Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch
Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KMS-1401MLJ OFF OFF OFF ON ON ON ON OFF OFF OFF
S5 Dip Switch (Do Not Adjust)
Dip Switch No.
1
2
3
4
5
KMS-1401MLJ
ON ON OFF OFF OFF
b) Harvest Timer (S4 dip switch 1 & 2)
The harvest timer starts counting when the thermistor reads 48°F (9°C) at the evaporator 
outlet and the control board reads the thermistor's 3.9 kΩ signal. The harvest timer is 
factory set, and generally no adjustment is required. However, a setting longer than the 
factory setting may be advised in cases where the flush provided at harvest needs to be 
prolonged for extra cleaning. Before changing this setting, contact Hoshizaki Technical 
Support at 1-800-233-1940 for recommendations. Keep in mind that setting the harvest 
timer to a longer setting decreases 24-hour production.
Note that the pump-out timer (S4 dip switch 3 & 4) acts in place of the harvest timer 
during cycles with a pump-out. For details, see "II.C.3.c) Pump-Out Timer (S4 dip switch 
3 & 4)."
Dip Switch Setting
Time (seconds)
No. 1
No. 2
OFF
OFF
60
ON
OFF
90
OFF
ON
120
ON
ON
180
1
2
3
4
5
ON
1
2
3
4
5
6
7
8
9
10
ON
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5 & 6)
Pump-Out Timer (3 & 4)
Harvest Timer (1 & 2)
Harvest Pump Timer (7) (Do not adjust)
Factory Use (8)
S4 Dip Switch 
Do Not Adjust
S5 Dip Switch 
Refill Counter 
(2 through 5)
Float Switch 
Selector (1)