Справочник Пользователя для Mitsubishi Electronics SW2D5C-GTD2-E
5.2 Communication Setup
5.2.7 How to Set Up the YOKOGAWA PLC Connection
5 - 53
1
OV
ER
VI
EW
2
SYS
TEM
CONFIGURA
T
ION
3
SPEC
IFI
CA
TIO
NS
4
SC
R
EE
N
CONF
IGURA
TION
5
O
PERA
T
IN
G
METHO
D
6
FUNC
TIONS
7
IN
TERN
AL
DE
VI
CE
IN
TE
R
FAC
E
FU
NCTION
8
TR
OU
BL
ES
HO
O
TI
N
G
A
PPENDICES
(5) Communications check
For communications check, refer to the following.
(6) Settings on GT Designer2 and GT SoftGOT1000.
(a) Setting on GT Designer2
Set the Ethernet setting dialog box on GT Designer as shown below.
(b) Setting on GT SoftGOT1000
Set the communication setup dialog box of GT SoftGOT1000.
For details on setting the communication setup dialog box, refer to the following manual.
For details on setting the communication setup dialog box, refer to the following manual.
Item
Description
Range
Host
Indicate the host station. (The host station is indicated as *.)
-
N/W No.
Set the network number of the target Ethernet module.
1 to 239
PC No.
Set the station number of the target Ethernet module
1 to 64
Type
Select [YOKOGAWA].
YOKOGAWA
IP address
Set the IP address of the target Ethernet module.
IP address of programmable
controller side
controller side
Port No.
Set the port number of the target Ethernet module.
12289, 12291
Communication
Select a communication method.
UDP, TCP