Справочник Пользователя для Mitsubishi Electronics SW2D5C-GTD2-E

Скачать
Страница из 234
5.2   Communication Setup
5.2.6   How to Set Up the YASKAWA PLC Connection
5 - 51
1
OV
ER
VI
EW
2
SYS
TEM 
CONFIGURA
T
ION
3
SPEC
IFI
CA
TIO
NS
4
SC
R
EE
N
 
CONF
IGURA
TION
5
O
PERA
T
IN
METHO
D
6
FUNC
TIONS
7
IN
TERN
AL
 DE
VI
CE 
IN
TE
R
FAC
FU
NCTION
8
TR
OU
BL
ES
HO
O
TI
N
G
A
PPENDICES
(6) Settings on GT Designer2 and GT SoftGOT1000.
(a) Setting on GT Designer2
Set the Ethernet setting dialog box on GT Designer as shown below.
(b) Setting on GT SoftGOT1000
Set the communication setup dialog box of GT SoftGOT1000.
For details on the communication setting, refer to the following manual.
Item
Description
Range
Host
Indicate the host station. (The host station is indicated as *.)
-
N/W No.
Set the network number of the target Ethernet module.
1 to 239
PLC No.
Set the station number of the target Ethernet module.
1 to 64
Type
Select [YASKAWA].
YASKAWA
IP address
Set the IP address of the target Ethernet module.
IP address of programmable 
controller side
Port No.
Set the port number of the target Ethernet module.
256 to 65534
Communication
Select a communication method.
UDP, TCP