Replacing the pre-
separation pad
Change the pre-separation pad when the frequency of multi-fed 
documents increases.
1. Open the scanner cover.
2. Remove the pre-separation pad by lifting the pad up and out of 
position.
NOTE: The pre-separation pad fits snuggly in place; therefore, a 
little force may be required to remove it.
3. Install the new pre-separation pad. Be sure it snaps into place.
4. Close the scanner cover.
Replacing the imaging 
guides
Replace the imaging guides when they become damaged or heavily 
scratched. See the section entitled, “Cleaning the optics” earlier in this 
chapter for detailed procedures about removing the imaging guides.
1. Open the scanner cover.
2. Gently pull the 2 fastening clips that secure the top imaging guide 
towards the front of the scanner to release and remove the imaging 
guide from the transport.
3. Install the new imaging guide into the scanner by holding the frame 
of the imaging guide so that the fastening clips are on the back side. 
Slide the guides under the transport tray towards the feeder table 
and ease the back side of the imaging guide into position.
4. Repeat Steps 2 and 3 to replace the bottom imaging guide.
5. Close the scanner cover.
Lamps (LEDs)
IMPORTANT: The LEDs on Ngenuity scanners should NOT be cleaned 
or wiped with any type of wipes and/or solvent.
The LED illumination system on Ngenuity Scanners should last the life 
of the scanner with normal use. If something happens that requires the 