Справочник Пользователя для Lucent Technologies Release 8.2
Configuration 2: R7r (+CMS) <—ethernet—> R7csi
3
C-LAN Administration
Administration for Network Connectivity
CID: 77730
555-233-504 — Issue 1 — April 2000
80
Switch 1 Task — Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on the
node 1 switch.
node 1 switch.
Begin
Steps
>
Open the Processor Channel Assignment form — enter
ch com p
> Enter values
change communications-interface processor-channels
Page 1 of X
Page 1 of X
PROCESSOR CHANNEL ASSIGNMENT
Proc Gtwy Interface Destination Session Mach
Chan Enable Appl. To Mode Link/Chan Node Port Local/Remote ID
1:
Chan Enable Appl. To Mode Link/Chan Node Port Local/Remote ID
1:
y mis____
s
2_ 5001__ node-2____ 0____ 1
_
1_ __
2:
n
_______
_ __ _____ __________ 0____ ___ ___ __
3:
n
_______
_ __ _____ __________ 0____ ___ ___ __
4:
n
_______
_ __ _____ __________
0____ ___ ___ __
:
12: y
dcs ___ s 2_ 5003__ node-5____ 0____ 12_
21_ 2_
:
64:
n
________
_ __ _____ __________ 0____ ___ ___ __
Field
Conditions/Comments
Processor Channel 1
: (connection to CMS)
Enable
Set to
y
.
Appl.
Enter
mis
for the CMS connection on Processor Channel 1.
Mode
Set the Mode to
s
(“server”) on both switches for connections
to CMS.
Interface Link
This must match the link number assigned on the node-1 data
module screen.
module screen.
Interface Chan
For TCP/IP, interface channel numbers are in the range 5000
– 64500.
– 64500.
The recommended values are: 5001 for CMS, 5002 for Intuity
AUDIX, and 5003 for DCS connections that are not
gateways. These three values should be reused for multiple
instances of these applications; for example, if there are two
Intuity AUDIX’s, use 5002 for both; or if there are four
DEFINITY ECS’s, use 5003 for all four. The combination of
Link, Interface Channel, and Mach ID must be unique.
AUDIX, and 5003 for DCS connections that are not
gateways. These three values should be reused for multiple
instances of these applications; for example, if there are two
Intuity AUDIX’s, use 5002 for both; or if there are four
DEFINITY ECS’s, use 5003 for all four. The combination of
Link, Interface Channel, and Mach ID must be unique.
The recommended values for gateway switches is 6001–6099.
The interface channel number must be unique for each
gateway.
The interface channel number must be unique for each
gateway.
1 of 3