Справочник Пользователя для Lucent Technologies Release 8.2

Скачать
Страница из 524
Configuration 2: R7r (+CMS) <—ethernet—> R7csi 
79
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000
CID: 77730
3  
C-LAN Administration
Switch 1 Task — Assign Link via ethernet Data Module to the LAN  
This task administers an ethernet data module for the ethernet connection to the CMS 
adjunct and to Switch 2. The data module defines a network interface — it associates 
a link number with a port address and node name for the C-LAN port used for this 
connection.
Begin
Steps
> Open Data Module form — enter  
a da n
> Enter values
> Submit the screen
End
add data-module next 
                                                                  Page 1 of X
                          
DATA MODULE
    Data Extension: 2377            Name: ethernet on link 2
 
Type: ethernet
              Port: 01c0817_
              Link: 2 
Network uses 1’s for broadcast addresses? y
Field
Conditions/Comments
Type:
This indicates the data-module type for this link.
Port:
Ethernet connections must be assigned to port 17 on the C-LAN 
circuit pack.
Link:
The link number must be in the range 1 – 33 (for G3r), not 
previously assigned on this switch.
Name:
This field is information-only; it appears in lists generated by the 
“list data module” command.
Network 
uses 1’s for 
broadcast 
addresses?
Leave the default (
y
) if the private network contains only 
DEFINITY switches and adjuncts. Set to 
n
 only if the network 
includes non-DEFINITY switches that use the 0’s method of 
forming broadcast addresses. See Appendix A, “Data Module - 
type ethernet” for more information about this field.