Справочник Пользователя для Lucent Technologies Release 8.2

Скачать
Страница из 524
Configuration 3: R8si<—x.25 —> R8r Gateway 
<—ethernet—> R8si 
115
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000
CID: 77730
3  
C-LAN Administration
Switch 2 Task — Assign Processor Channels
This task associates data links (hardware) with processor channels (software) on 
Switch 2.
Begin
Steps
> Open Processor Channel Assignment form — enter  
ch com p
Note:
The Processor Channel number, the Interface Channel number, and the 
Local and Remote Session numbers do not need to be the same number 
but they should be made the same whenever possible to simplify network 
“bookkeeping” and diagnostics.
> Enter values
change communications-interface processor-channels
                                                                Page 1 of X
PROCESSOR CHANNEL ASSIGNMENT
Proc                Gtwy        Interface    Destination      Session    Mach
Chan Enable  Appl.  To  Mode  Link/Chan   Node       Port  Local/Remote  ID
  1: 
_______
 _    __  _____  _________  0____  ___   ___    __
  2: 
_______
 _    __  _____  _________  0____  ___   ___    __
   :
21:    y dcs____ 
 _ 
 2_   21___
_________ 0____  21_   21_    1_
23:    y
 dcs____ 
_  2_ 23___
_________ 0_
_
23_   23_    3_
   :    
256: n 
_______
_    __  _____  _________  0____  ___   ___    __
Field
Conditions/Comments
Processor Channel 21
: (X.25 connection to Switch 1)
Enable
Set to 
y
.
Appl.
Set to 
dcs
 for DCS signaling.
Mode
Used for TCP/IP connections only.
Interface Link
This must match the link number assigned on the procr-intf 
data module screen.
Interface Chan
The interface channel number must be in the range 1 – 64 
for an X.25 link.
Destination Node
Used for TCP/IP connections only.
Destination Port
Used for TCP/IP connections only.
1 of 2