Configuration 5A: R8csi <—ppp—> R8r (one C-LAN) 
<—ethernet—> R8si 
153
Administration for Network Connectivity
555-233-504 — Issue 1 — April 2000
CID: 77730
3  
C-LAN Administration
Switch 1 Task — Assign Link via ethernet Data Module to Ethernet
This task administers an ethernet data module for the ethernet connection to node 3. 
The data module associates a link number with a port address, extension number, and 
node name for the C-LAN port used for this connection.
Begin
Steps
> Open Data Module form — enter  
a da n
> Enter values
> Submit the screen
End
add data next 
                                                                  Page 1 of X
                          DATA MODULE
    Data Extension: 2377            Name: ethernet on link 2
 
BCC: 2
              Type: ethernet
              Port: 01c0817_
              Link: 2 
Network uses 1’s for broadcast addresses? y
Field
Conditions/Comments
Type:
This indicates the data-module type for this connection.
Port:
Ethernet connections must be assigned to port 17 on the C-LAN 
circuit pack.
Link:
The link number must be in the range 1 – 33 (for R8r), not 
previously assigned on this switch.
Name:
Information-only; appears in list generated by the “list data 
module” command.
Network uses 
1’s for 
broadcast 
addresses?
Leave the default (
y
) if the private network contains only 
DEFINITY switches and adjuncts. Set to 
n
 only if the network 
includes non-DEFINITY switches that use the 0’s method of 
forming broadcast addresses. See Appendix A, “Data Module - 
type ethernet” for more information about this field.