Overview 
3  
C-LAN Administration
Administration for Network Connectivity
CID: 77730
555-233-504 — Issue 1 — April 2000
58
In the hardware part of the diagram, the paths for voice and signaling data are shown 
by dashed or dotted lines. The data for voice and call-setup signaling usually takes a 
different path through the switch hardware from the path for DCS and ISDN signaling 
data. These two types of data are distinguished in the hardware part of the diagram by 
the following convention.
A dashed line, "
", indicates voice and call-setup data. 
A dotted line, "
 ", indicates DCS signaling data.
In the software part of the diagram, the virtual path from processor to processor 
between two nodes is traced by dashed lines. The path starts at a processor channel on 
one node, through the link/interface-channels on each node, to the processor channel 
on the connected node.
Administration tasks
This section gives the detailed steps for administering the connections between 
switches. For each configuration, there are several tasks and each task consists of 
several steps. All of the tasks needed to administer all the nodes in the network are 
included in each configuration.
The administration task sections list the steps for completing a screen (or "form") and 
show a representation of the filled-in screen. Many of the field values shown in the 
screens are examples — you will use different values that are appropriate for your 
system. Information about the fields and their values — when and why different 
values are used — is given for each screen. More detailed information about the 
screens and their fields is given in Appendix A.
Supported Switches and Adjuncts
Csi-model switches cannot have X.25 connections. New R8si and R8r switches 
cannot have new X.25 connections but pre-R7 switches with X.25 connections can be 
upgraded to R8 and keep the X.25 connections.
The vs model of DEFINITY ECS cannot be upgraded to R8 — R6.3 is the last release 
supported for the vs model. However, pre-R7 releases of the vs model will be 
supported (via X.25 and ISDN, not TCP/IP) in customer networks that include R8 
versions of the csi, si, and r models.
The call management system (CMS) and Intuity adjuncts can be connected to the 
DEFINITY ECS R7csi with an ethernet connection and to the si and r models with 
either an ethernet or Bx.25 connection. Procedures for administering these 
connections are not covered in this book. They are documented in CentreVu CMS 
Switch Connections and Administration
 (585-215-876) for CMS and in Intuity 
Messaging Solutions, LAN Integration with DEFINITY ECS
 (585-313-602) for 
Intuity. CMS administration is covered in Centre CMS Software Installation and 
Setup
, 585-215-866.