Enable links and processor channels
You must enable links and processor channels before the connections can be used.
To enable a link, open its data module screen (
ch da
[
ext
]) and set the Enable
Link? field to
y
.
[note: to view a list of assigned data modules and their extensions, enter the “list
data-module” command (
data-module” command (
l da
)]
To enable the processor channels, open the processor channel screen (
ch com p
)
and set the Enable field to
y
for each assigned processor channel.
Note:
1. You must disable a link or processor channel before you can change its
parameters.
parameters.
Note:
2. The busy-out command overrules the data module Enable Link? field.
Note:
3. On the C-LAN boards, low-level connectivity can remain intact when
higher-level applications such as DCS are not functioning. For example,
an external ping to a C-LAN’s ethernet port could be successful even
when the board is busied-out. When debugging connectivity problems,
pinging only checks low-level connectivity.
higher-level applications such as DCS are not functioning. For example,
an external ping to a C-LAN’s ethernet port could be successful even
when the board is busied-out. When debugging connectivity problems,
pinging only checks low-level connectivity.