6.  Upgrading Firmware
Upgrading Firmware Using the Web Upgrade
qêçìÄäÉëÜççíáåÖ=bíÜÉêåÉí=`çããìåáÅ~íáçå
Use the following steps to determine the IP address of the PDS, and establish proper 
communications:
1. 
Power-up the PDS.
2. 
Note the PDS’s current IP address:
a. 
From the Status Menu, press SEL to display the Setup Menu.
b. 
Select System to display the System Menu.
c. 
Select Ethernet to display the Ethernet Menu.
d. 
Make a note of the information on the IP line, which shows the current IP 
address in all modes (with DHCP on or off).
3. 
Attempt to ping the PDS as follows:
a. 
Connect the PDS’s Ethernet port to a Switch.  
b. 
Connect the Ethernet Switch to your PC.  
c. 
Turn on the PC or laptop.
d. 
Open a command prompt window on the PC.  Click Start > Programs > 
Accessories > Command Prompt
.
e. 
On the command prompt line, type: 
ping 192.168.0.10
... followed by Enter
f. 
If the computer can successfully communicate with the PDS, you will see 
a series of “replies” from the target IP address.  Repeat the upgrade 
procedure as outlined in the “
” section on page 100.
g. 
If you see a “Request timed out” message, the PC is unable to locate 
the PDS.  If this is the case:
Check your network connections and settings as described 
above, or,
Contact your network administrator, or,
Contact Technical Support.  In Appendix C, refer to the 
” section on page 174 for details.
Note
Use the unit’s actual IP address, as determined in step 2 
above.